The Temperature Ceiling Itself: Maximum Temperature of a Radiation Bath Under the Bound Density, Across Species Counts

At the Standard Model count the ceiling is 1.05e+09 GeV, or 1.21e+22 K. The species dependence is weak, as the fourth root requires: at g* = 10.75 the ceiling rises to 1.86e+09 GeV, and even a thousand relativistic species lower it only to 5.97e+08 GeV. The carrier dependence is the opposite story: the electron branch would place the ceiling at 2.44e+07 GeV, nearly three orders of magnitude lower, which would rewrite the conclusions of every high-scale transition study. The ceiling used throughout this territory therefore stands or falls with the carrier-selection argument, and that argument, confinement of the spin carrier with the matter whose density is being bounded, is the load-bearing assumption readers should examine first. This study is simulated and computed from stated assumptions; it is not a measurement.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-11
DOI
https://doi.org/10.5281/zenodo.24145467
Primary Topic
Particle physics theoretical and experimental studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

The Temperature Ceiling Itself: Maximum Temperature of a Radiation Bath Under the Bound Density, Across Species Counts

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Particle physics theoretical and experimental studies
article

The Temperature Ceiling Itself: Maximum Temperature of a Radiation Bath Under the Bound Density, Across Species Counts

William Alexander Aldred
article en

Abstract

At the Standard Model count the ceiling is 1.05e+09 GeV, or 1.21e+22 K. The species dependence is weak, as the fourth root requires: at g* = 10.75 the ceiling rises to 1.86e+09 GeV, and even a thousand relativistic species lower it only to 5.97e+08 GeV. The carrier dependence is the opposite story: the electron branch would place the ceiling at 2.44e+07 GeV, nearly three orders of magnitude lower, which would rewrite the conclusions of every high-scale transition study. The ceiling used throughout this territory therefore stands or falls with the carrier-selection argument, and that argument, confinement of the spin carrier with the matter whose density is being bounded, is the load-bearing assumption readers should examine first. This study is simulated and computed from stated assumptions; it is not a measurement.

Zenodo (CERN European Organization for Nuclear Research)
Particle physics theoretical and experimental studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon