Automated endoscope cleaning with turbulent hydro-aeric flow: Evaluation of infection control, ergonomics, workflow, and environmental impact

Background: Time-consuming, burdensome and prone to human error, manual cleaning is the first step of endoscope reprocessing and remains mandatory. Devices automating this step using turbulent hydro-aeric flow (THAF) could bring organizational and environmental benefits. We performed a multiscale evaluation of THAF-assisted cleaning. Methods: The four-pronged assessment of THAF-assisted cleaning comprised: (1) a multicenter microbiological study comparing protein/hemoglobin residue and bacterial contamination after THAF-assisted vs manual cleaning; (2) an ergonomic study of hardship factors associated with cleaning; (3) an efficiency study of time consumption and organizational impact; (4) a life cycle assessment comparing the environmental impact of THAF and manual cleaning methods. Results: Protein/hemoglobin residue was detected after cleaning in 8/50 endoscopes (16%) with manual and 8/34 (24%) with THAF (p=0.41). After complete reprocessing, alert-level contamination occurred in 2/50 (4%) vs 2/34 (6%) (p=1.0) and action-level in 4/50 (8%) vs 6/34 (18%) (p=0.30). THAF halved cleaning time, reduced observed exposure to repetitiveness, moisture, detergent and constrained working postures, and enabled one nurse to operate two stations. In a medium-sized center cleaning 6,800 endoscopes a year, THAF would add €1,890 while avoiding emissions of 1.79 metric-tons CO₂e, 250kg of medical waste and the consumption of 306L of detergent and 200,804L of water. Conclusion: THAF-assisted cleaning reduced dedicated cleaning time, exposure to occupational hardship factors, greenhouse gas emissions, water and detergent consumption as well as waste production. In this exploratory study, which was not powered to establish non-inferiority, contamination rates were not statistically different from those observed after manual cleaning.

Authors

Institutions

Publication Details

Journal
Endoscopy International Open
Published
2026-11-11
DOI
https://doi.org/10.1055/a-3002-3654
Primary Topic
Medical Device Sterilization and Disinfection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Automated endoscope cleaning with turbulent hydro-aeric flow: Evaluation of infection control, ergonomics, workflow, and environmental impact

Mathieu Pioche, Cédric Dananché, Enrique Pérez‐Cuadrado‐Robles, Jean-Noël Lorenzi et al.
Endoscopy International Open
Medical Device Sterilization and Disinfection
article

Automated endoscope cleaning with turbulent hydro-aeric flow: Evaluation of infection control, ergonomics, workflow, and environmental impact

Mathieu Pioche, Cédric Dananché, Enrique Pérez‐Cuadrado‐Robles, Jean-Noël Lorenzi, Frédéric Prat, Gabriel Marcellier, Stéphane Koch, Jean‐Baptiste Chevaux, Inès De Maisoncelle, Davuth Tan, Charlotte Moreau, Mélanie Bernard, Mahaut Hugot
article en

Abstract

Background: Time-consuming, burdensome and prone to human error, manual cleaning is the first step of endoscope reprocessing and remains mandatory. Devices automating this step using turbulent hydro-aeric flow (THAF) could bring organizational and environmental benefits. We performed a multiscale evaluation of THAF-assisted cleaning. Methods: The four-pronged assessment of THAF-assisted cleaning comprised: (1) a multicenter microbiological study comparing protein/hemoglobin residue and bacterial contamination after THAF-assisted vs manual cleaning; (2) an ergonomic study of hardship factors associated with cleaning; (3) an efficiency study of time consumption and organizational impact; (4) a life cycle assessment comparing the environmental impact of THAF and manual cleaning methods. Results: Protein/hemoglobin residue was detected after cleaning in 8/50 endoscopes (16%) with manual and 8/34 (24%) with THAF (p=0.41). After complete reprocessing, alert-level contamination occurred in 2/50 (4%) vs 2/34 (6%) (p=1.0) and action-level in 4/50 (8%) vs 6/34 (18%) (p=0.30). THAF halved cleaning time, reduced observed exposure to repetitiveness, moisture, detergent and constrained working postures, and enabled one nurse to operate two stations. In a medium-sized center cleaning 6,800 endoscopes a year, THAF would add €1,890 while avoiding emissions of 1.79 metric-tons CO₂e, 250kg of medical waste and the consumption of 306L of detergent and 200,804L of water. Conclusion: THAF-assisted cleaning reduced dedicated cleaning time, exposure to occupational hardship factors, greenhouse gas emissions, water and detergent consumption as well as waste production. In this exploratory study, which was not powered to establish non-inferiority, contamination rates were not statistically different from those observed after manual cleaning.

Endoscopy International Open
Université Paris Cité (FR), Hôpital Beaujon (FR), Centre Hospitalier Universitaire de Besançon (FR), Assistance Publique – Hôpitaux de Paris (FR), Centre Hospitalier Régional et Universitaire de Nancy (FR), Hospices Civils de Lyon (FR), Hôpital Européen Georges-Pompidou (FR), Hôpital Edouard Herriot (FR), Centre International de Recherche en Infectiologie (FR)
Medical Device Sterilization and Disinfection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon