Commercially available objective gait evaluation systems show good to excellent reliability in horses across hard-surface types and multiple operators

Abstract Objective To evaluate the intrasystem reliability of an AI-based smartphone application Sleip (AI-SPA), the inertial measurement unit (IMU) system Equinosis Q Lameness Locator (LL), and the IMU system Equisym (ES) across 2 different hard surfaces and to assess the interoperator reliability for the 2 IMU systems. Methods 8 mixed-breed research horses, aged 4 to 12 years, with varying degrees of gait asymmetries were utilized. To assess intrasystem reliability, horses were in-hand, straight-line trotted on either epoxy-coated concrete or rubber-coated concrete. Three trials were performed for LL and ES, while 6 concurrent trials were performed for AI-SPA. Interoperator reliability was assessed with 4 operators on the rubber-coated concrete only. Intraclass correlation coefficients and SE of measurements were calculated for 4 outcome parameters common to all systems as well as a variety of system-specific outcome parameters for LL and ES. Results Nearly all intraclass correlation coefficients indicated moderate to excellent intrasystem reliability (> 0.50) across the 3 systems (AI-SPA, 0.40 to 0.85; LL, 0.73 to 0.94; ES, 0.44 to 0.99) and were comparable between surfaces. Interoperator reliability was moderate to excellent for both LL (0.72 to 0.92) and ES (0.73 to 0.96). Standard error of measurement values remained relatively stable across study conditions. Conclusions Despite inherent horse variability and minor differences in testing conditions, objective gait evaluation systems consistently produced measurements indicating moderate to excellent reliability and low measurement error. Clinical Relevance These findings indicate that observed changes in system output are unlikely to be impacted by operator or hard-surface effects, supporting clinical reliability of these systems in routine practice when utilizing manufacturers’ instructions.

Authors

Institutions

Publication Details

Journal
Journal of the American Veterinary Medical Association
Published
2026-11-11
DOI
https://doi.org/10.2460/javma.26.06.0495
Primary Topic
Veterinary Equine Medical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Commercially available objective gait evaluation systems show good to excellent reliability in horses across hard-surface types and multiple operators

Allen E. Page, Emma Adam, Olivia Jacob, Jenna L. McPeek et al.
Journal of the American Veterinary Medical Association
Veterinary Equine Medical Research
article

Commercially available objective gait evaluation systems show good to excellent reliability in horses across hard-surface types and multiple operators

Allen E. Page, Emma Adam, Olivia Jacob, Jenna L. McPeek, Sophia Carattini, Adrianne Caudill
article en

Abstract

Abstract Objective To evaluate the intrasystem reliability of an AI-based smartphone application Sleip (AI-SPA), the inertial measurement unit (IMU) system Equinosis Q Lameness Locator (LL), and the IMU system Equisym (ES) across 2 different hard surfaces and to assess the interoperator reliability for the 2 IMU systems. Methods 8 mixed-breed research horses, aged 4 to 12 years, with varying degrees of gait asymmetries were utilized. To assess intrasystem reliability, horses were in-hand, straight-line trotted on either epoxy-coated concrete or rubber-coated concrete. Three trials were performed for LL and ES, while 6 concurrent trials were performed for AI-SPA. Interoperator reliability was assessed with 4 operators on the rubber-coated concrete only. Intraclass correlation coefficients and SE of measurements were calculated for 4 outcome parameters common to all systems as well as a variety of system-specific outcome parameters for LL and ES. Results Nearly all intraclass correlation coefficients indicated moderate to excellent intrasystem reliability (> 0.50) across the 3 systems (AI-SPA, 0.40 to 0.85; LL, 0.73 to 0.94; ES, 0.44 to 0.99) and were comparable between surfaces. Interoperator reliability was moderate to excellent for both LL (0.72 to 0.92) and ES (0.73 to 0.96). Standard error of measurement values remained relatively stable across study conditions. Conclusions Despite inherent horse variability and minor differences in testing conditions, objective gait evaluation systems consistently produced measurements indicating moderate to excellent reliability and low measurement error. Clinical Relevance These findings indicate that observed changes in system output are unlikely to be impacted by operator or hard-surface effects, supporting clinical reliability of these systems in routine practice when utilizing manufacturers’ instructions.

Journal of the American Veterinary Medical Association
University of Kentucky (US)
Veterinary Equine Medical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon