A Polarised-Film Radiation Dosimeter: Computed Dose Response, Minimum Detectable Dose and Range of a Spin-Polarised Film Badge

Radiation dose in a polarised material leaves a permanent record: ionising events destroy polarisation in proportion to dose, and a polarimetric readout afterwards recovers the accumulated exposure. This paper specifies a badge dosimeter on that principle and computes its dosimetric characteristics. With a depolarisation constant of 0.35 per gray and a polarimeter readout precision of 1.0e-4 in polarisation fraction, the minimum detectable dose is 0.29 milligray; the response stays within ten per cent of linear to 0.29 gray; and saturation at ninety-eight per cent depolarisation gives an upper range of 11.2 gray, a dynamic range of 3.91e+04. Fading is specified at 1.5 per cent per month at room temperature. SIMULATED, NOT MEASURED: the badge is specified and its response computed from the stated calibration constant; no film has been irradiated.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-11
DOI
https://doi.org/10.5281/zenodo.24129861
Citations
1
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
3.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Polarised-Film Radiation Dosimeter: Computed Dose Response, Minimum Detectable Dose and Range of a Spin-Polarised Film Badge

William Alexander Aldred
1 citations
Zenodo (CERN European Organization for Nuclear Research)
Radiation Detection and Scintillator Technologies
3.33
article

A Polarised-Film Radiation Dosimeter: Computed Dose Response, Minimum Detectable Dose and Range of a Spin-Polarised Film Badge

William Alexander Aldred
article en
1 citations

Abstract

Radiation dose in a polarised material leaves a permanent record: ionising events destroy polarisation in proportion to dose, and a polarimetric readout afterwards recovers the accumulated exposure. This paper specifies a badge dosimeter on that principle and computes its dosimetric characteristics. With a depolarisation constant of 0.35 per gray and a polarimeter readout precision of 1.0e-4 in polarisation fraction, the minimum detectable dose is 0.29 milligray; the response stays within ten per cent of linear to 0.29 gray; and saturation at ninety-eight per cent depolarisation gives an upper range of 11.2 gray, a dynamic range of 3.91e+04. Fading is specified at 1.5 per cent per month at room temperature. SIMULATED, NOT MEASURED: the badge is specified and its response computed from the stated calibration constant; no film has been irradiated.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 15%
Radiation Detection and Scintillator Technologies
3.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon