A Torsion-Assisted Electrolysis Plant: Cell Voltage and Hydrogen Output for Polarised Feed Water

This paper presents a complete design study of an electrolysis plant whose feed water is spin-polarised before it reaches the stack, computed throughout from stated assumptions. The plant produces 1.44 kg of hydrogen per hour. At a polarised fraction of 0.6 the cell voltage falls to 1.691 V from 1.830 V unpolarised, and the specific energy falls to 46.85 kWh per kilogram from 50.68, a saving of 7.6 percent, against a reversible-voltage floor of 34.07 kWh per kilogram that no polarisation can move. Every figure is a computed result of the stated model and nothing was built or tested: the study is SIMULATED, NOT MEASURED, and its limits are stated as plainly as its performance.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-11
DOI
https://doi.org/10.5281/zenodo.24125771
Citations
1
Primary Topic
Hybrid Renewable Energy Systems
Type
article
Field-Weighted Citation Impact
1.31
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Torsion-Assisted Electrolysis Plant: Cell Voltage and Hydrogen Output for Polarised Feed Water

William Alexander Aldred
1 citations
Zenodo (CERN European Organization for Nuclear Research)
Hybrid Renewable Energy Systems
1.31
article

A Torsion-Assisted Electrolysis Plant: Cell Voltage and Hydrogen Output for Polarised Feed Water

William Alexander Aldred
article en
1 citations

Abstract

This paper presents a complete design study of an electrolysis plant whose feed water is spin-polarised before it reaches the stack, computed throughout from stated assumptions. The plant produces 1.44 kg of hydrogen per hour. At a polarised fraction of 0.6 the cell voltage falls to 1.691 V from 1.830 V unpolarised, and the specific energy falls to 46.85 kWh per kilogram from 50.68, a saving of 7.6 percent, against a reversible-voltage floor of 34.07 kWh per kilogram that no polarisation can move. Every figure is a computed result of the stated model and nothing was built or tested: the study is SIMULATED, NOT MEASURED, and its limits are stated as plainly as its performance.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 24%
Hybrid Renewable Energy Systems
1.31
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon