Automated Fetal Intracranial Volume Z-Scores and Multi-Vessel Doppler Velocimetry for the Assessment of Fetal Brain Growth in Severe Fetal Growth Restriction: A Retrospective Cross-Sectional Study

Abstract Objective. To evaluate automated three-dimensional fetal intracranial volume (ICV) measurement, alone and combined with multi-vessel Doppler indices, for assessing fetal brain growth in severe fetal growth restriction (FGR), and to quantify its repeatability. Methods. This retrospective cross-sectional study included 111 examinations in 110 women with severe FGR and 235 controls undergoing automated ICV measurement (Smart ICV) and multi-vessel Doppler assessment. ICV, estimated fetal weight (EFW), and Doppler indices were expressed as gestational-age-adjusted Z-scores. Analyses included group comparisons, ROC analysis, bootstrap-validated logistic models, repeatability assessment, and external-reference validation. Results. ICV Z-score was lower in severe FGR than in controls (− 2.27 ± 1.55 vs − 0.05 ± 1.08; P < 0.0001), as was EFW Z-score; the brain–body dissociation index (ICV Z minus EFW Z) was + 2.06 vs − 0.08 (P < 0.0001), consistent with adaptive head sparing. ICV Z-score discriminated severe FGR from controls with an AUC of 0.907 (95% CI 0.876–0.935; sensitivity 82.0%, specificity 85.4%). In the Doppler subset, the combined ICV + cerebroplacental ratio (CPR) model achieved an AUC of 0.923 with good calibration (optimism-corrected AUC 0.918), without significant improvement over ICV alone (P = 0.118). Repeatability was excellent (ICC 0.998, within-subject CV 1.98%). External-reference Z-scores correlated strongly with internal values (r = 0.910). Conclusion. Automated ICV Z-scoring demonstrates high diagnostic performance for identifying reduced fetal brain growth in severe FGR and reveals head sparing; adding CPR yields a well-calibrated model without significant incremental discrimination. Automated ICV volumetry is a promising adjunct to Doppler surveillance; prospective outcome-linked validation is warranted.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-11
DOI
https://doi.org/10.21203/rs.3.rs-11240382/v1
Primary Topic
Pregnancy and preeclampsia studies
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Automated Fetal Intracranial Volume Z-Scores and Multi-Vessel Doppler Velocimetry for the Assessment of Fetal Brain Growth in Severe Fetal Growth Restriction: A Retrospective Cross-Sectional Study

Ruili Wang, Xueli Zhang, Yuan Gao, Zhaoling Zhu et al.
Research Square
Pregnancy and preeclampsia studies
preprint

Automated Fetal Intracranial Volume Z-Scores and Multi-Vessel Doppler Velocimetry for the Assessment of Fetal Brain Growth in Severe Fetal Growth Restriction: A Retrospective Cross-Sectional Study

Ruili Wang, Xueli Zhang, Yuan Gao, Zhaoling Zhu, Ziyi Wang
preprint en

Abstract

Abstract Objective. To evaluate automated three-dimensional fetal intracranial volume (ICV) measurement, alone and combined with multi-vessel Doppler indices, for assessing fetal brain growth in severe fetal growth restriction (FGR), and to quantify its repeatability. Methods. This retrospective cross-sectional study included 111 examinations in 110 women with severe FGR and 235 controls undergoing automated ICV measurement (Smart ICV) and multi-vessel Doppler assessment. ICV, estimated fetal weight (EFW), and Doppler indices were expressed as gestational-age-adjusted Z-scores. Analyses included group comparisons, ROC analysis, bootstrap-validated logistic models, repeatability assessment, and external-reference validation. Results. ICV Z-score was lower in severe FGR than in controls (− 2.27 ± 1.55 vs − 0.05 ± 1.08; P < 0.0001), as was EFW Z-score; the brain–body dissociation index (ICV Z minus EFW Z) was + 2.06 vs − 0.08 (P < 0.0001), consistent with adaptive head sparing. ICV Z-score discriminated severe FGR from controls with an AUC of 0.907 (95% CI 0.876–0.935; sensitivity 82.0%, specificity 85.4%). In the Doppler subset, the combined ICV + cerebroplacental ratio (CPR) model achieved an AUC of 0.923 with good calibration (optimism-corrected AUC 0.918), without significant improvement over ICV alone (P = 0.118). Repeatability was excellent (ICC 0.998, within-subject CV 1.98%). External-reference Z-scores correlated strongly with internal values (r = 0.910). Conclusion. Automated ICV Z-scoring demonstrates high diagnostic performance for identifying reduced fetal brain growth in severe FGR and reveals head sparing; adding CPR yields a well-calibrated model without significant incremental discrimination. Automated ICV volumetry is a promising adjunct to Doppler surveillance; prospective outcome-linked validation is warranted.

Research Square
Zhengzhou University (CN), Henan Provincial People's Hospital (CN)
Pregnancy and preeclampsia studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon