A Review of Artificial Intelligence for Data Center Energy Efficiency: Toward Bridging the IT–Cooling Divide
Data centers consume vast amounts of electricity, and cooling still accounts for a large share of it. Artificial intelligence is increasingly used to reduce this demand, but computing resources and cooling are usually optimized as two separate problems, a separation we call the IT–cooling divide. This review examines how AI is applied to cooling, to Information and Communication Technology (ICT) resources, and to the data center as a whole (Full-DC). We searched Scopus and Web of Science (last searched on 3 August 2026) for journal articles published in 2021–2025 that report quantitative results. We supplemented the database search with a targeted search of ScienceDirect and reference checking. We report the process following PRISMA 2020. As no formal risk-of-bias tool exists for simulation-based engineering studies, the validation level and baseline of each study were recorded, and results were synthesized narratively. The first author selected 45 studies (16 cooling, 21 ICT, 8 Full-DC) on the basis of titles and abstracts and read all of them in full for data extraction. Because selection was made by a single reviewer, the reported shares describe the reviewed sample rather than the whole literature; a reproducible re-screening of all 933 database records, checked double-blind by both authors, indicates that reinforcement learning is over-represented, and metaheuristics under-represented, in this sample. Reinforcement learning is the most frequent primary approach for control and deep learning for prediction. Energy results are heterogeneous: they use different baselines (PID control, heuristics, competing algorithms), are reported at different levels (cooling plant, IT servers, network, or facility), and come almost entirely from simulation, trace-driven, or offline evaluations; no included study reports closed-loop deployment in production. Among the studies reporting an energy reduction in percent, the median value is about 9% for cooling (n = 7) and 13% for ICT (n = 7), and the two Full-DC studies report 16–17%. Only two included studies explicitly co-optimize computing and cooling decisions. Joint IT–cooling optimization therefore remains a promising but thinly tested direction, and progress depends on facility-level reporting, real-world validation, and open datasets. The review was not registered and received no external funding.
Authors
- Mohamed Bezza (ORCID: https://orcid.org/0009-0001-6926-8289)
- MOUNA NASSIM (ORCID: https://orcid.org/0009-0008-2337-5610)
Institutions
- Université Hassan II Mohammedia (MA)
- University of Hassan II Casablanca (MA)
Publication Details
- Journal
- Energies
- Published
- 2026-11-11
- DOI
- https://doi.org/10.3390/en19225417
- Primary Topic
- Energy Efficiency in Computing
- Type
- article
- Field-Weighted Citation Impact
- 0.00