Greener validated spectrophotometric investigation optimized with Box–Behnken design for nimesulide in pharmaceutical formulations

Nimesulide was evaluated in pharmaceutical formulations by forming a coloured product with potassium permanganate (KMnO 4 ) under alkaline conditions (NaOH), and the resulting absorbance was monitored at 601 nm. A Box–Behnken design was employed to optimise reaction time, KMnO 4 concentration and nimesulide concentration. The selected operating conditions were 11 min reaction time, 0.001 M KMnO 4 , 0.028 M nimesulide and 0.1 M NaOH. Validation covered specificity, linearity, accuracy, precision, detection and quantitation limits, and robustness in line with ICH-oriented requirements. The method showed a linear response from 1.8 to 22.5 µg/mL; the LOD and LOQ were 0.56 and 1.70 µg/mL, respectively. Recovery values were 99.225–99.794%, while intraday and interday precision produced %RSD ranges of 0.201–0.763% and 0.342–1.025%, respectively. We also examined sustainability and practical performance using AGREE, BAGI, AES, EPPI, and RAPI. Taken together, the analytical and greenness results support using the procedure to determine nimesulide in bulk material and pharmaceutical formulations.

Authors

Institutions

Publication Details

Journal
BMC Chemistry
Published
2026-11-11
DOI
https://doi.org/10.1186/s13065-026-01960-5
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Greener validated spectrophotometric investigation optimized with Box–Behnken design for nimesulide in pharmaceutical formulations

Reem Hasan Obaydo, Nada H. Alsmail, Sk Manirul Haque, Yunusa Umar et al.
BMC Chemistry
Analytical Methods in Pharmaceuticals
article

Greener validated spectrophotometric investigation optimized with Box–Behnken design for nimesulide in pharmaceutical formulations

Reem Hasan Obaydo, Nada H. Alsmail, Sk Manirul Haque, Yunusa Umar, Ahmed Abu-Judeh
article en

Abstract

Nimesulide was evaluated in pharmaceutical formulations by forming a coloured product with potassium permanganate (KMnO 4 ) under alkaline conditions (NaOH), and the resulting absorbance was monitored at 601 nm. A Box–Behnken design was employed to optimise reaction time, KMnO 4 concentration and nimesulide concentration. The selected operating conditions were 11 min reaction time, 0.001 M KMnO 4 , 0.028 M nimesulide and 0.1 M NaOH. Validation covered specificity, linearity, accuracy, precision, detection and quantitation limits, and robustness in line with ICH-oriented requirements. The method showed a linear response from 1.8 to 22.5 µg/mL; the LOD and LOQ were 0.56 and 1.70 µg/mL, respectively. Recovery values were 99.225–99.794%, while intraday and interday precision produced %RSD ranges of 0.201–0.763% and 0.342–1.025%, respectively. We also examined sustainability and practical performance using AGREE, BAGI, AES, EPPI, and RAPI. Taken together, the analytical and greenness results support using the procedure to determine nimesulide in bulk material and pharmaceutical formulations.

BMC Chemistry
Ebla Private University (SY), Jubail Industrial College (SA)
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon