Analytical Validation of β‐Hydroxybutyrate Quantification in Feline Serum with the BT3500 Analyzer

BACKGROUND: Quantitative measurement of serum β-hydroxybutyrate (β-OHB) is essential for detecting and monitoring ketosis and ketoacidosis in diabetic cats, particularly in the era of sodium-glucose cotransporter two (SGLT2) inhibitors, where euglycemic ketoacidosis may occur. The BT3500 analyzer has not been analytically validated for β-OHB quantification in feline serum. OBJECTIVES: Analytically validate the Randox Ranbut enzymatic β-OHB assay on feline serum using the BT3500 chemistry analyzer, including evaluation of sample stability under refrigerated and frozen storage conditions. METHODS: Residual feline serum samples and pooled sera were used to assess intra-assay and inter-assay precision, spike-recovery accuracy across five concentration increments, linearity under serial dilution, and analytical sensitivity (LoB, LoD, LoQ). Short-term stability was evaluated at 4°C for 7 days and long-term stability at -20°C at predefined time points up to 360 days. RESULTS: ≥ 0.9998). LoB, LoD, and LoQ were 0.044, 0.091, and 0.150 mmol/L, respectively. β-OHB was stable at 4°C up to 6 days and at -20°C up to 180 days, while decreases exceeding the acceptance limit were observed at 360 days. CONCLUSIONS: The Randox β-OHB assay on the BT3500 demonstrated acceptable analytical performance in feline serum and is suitable for routine clinical use; frozen storage beyond 180 days may impact result accuracy.

Authors

Institutions

Publication Details

Journal
Veterinary Clinical Pathology
Published
2026-11-11
DOI
https://doi.org/10.1111/vcp.70163
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Analytical Validation of β‐Hydroxybutyrate Quantification in Feline Serum with the BT3500 Analyzer

Andrea Corsini, Alicia Maria Carrillo Heredero, Alessandro Tirolo, Maria Chiara Sabetti et al.
Veterinary Clinical Pathology
Clinical Laboratory Practices and Quality Control
article

Analytical Validation of β‐Hydroxybutyrate Quantification in Feline Serum with the BT3500 Analyzer

Andrea Corsini, Alicia Maria Carrillo Heredero, Alessandro Tirolo, Maria Chiara Sabetti, Francesca Fidanzio
article en

Abstract

BACKGROUND: Quantitative measurement of serum β-hydroxybutyrate (β-OHB) is essential for detecting and monitoring ketosis and ketoacidosis in diabetic cats, particularly in the era of sodium-glucose cotransporter two (SGLT2) inhibitors, where euglycemic ketoacidosis may occur. The BT3500 analyzer has not been analytically validated for β-OHB quantification in feline serum. OBJECTIVES: Analytically validate the Randox Ranbut enzymatic β-OHB assay on feline serum using the BT3500 chemistry analyzer, including evaluation of sample stability under refrigerated and frozen storage conditions. METHODS: Residual feline serum samples and pooled sera were used to assess intra-assay and inter-assay precision, spike-recovery accuracy across five concentration increments, linearity under serial dilution, and analytical sensitivity (LoB, LoD, LoQ). Short-term stability was evaluated at 4°C for 7 days and long-term stability at -20°C at predefined time points up to 360 days. RESULTS: ≥ 0.9998). LoB, LoD, and LoQ were 0.044, 0.091, and 0.150 mmol/L, respectively. β-OHB was stable at 4°C up to 6 days and at -20°C up to 180 days, while decreases exceeding the acceptance limit were observed at 360 days. CONCLUSIONS: The Randox β-OHB assay on the BT3500 demonstrated acceptable analytical performance in feline serum and is suitable for routine clinical use; frozen storage beyond 180 days may impact result accuracy.

Veterinary Clinical Pathology
University of Parma (IT)
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon