Continuous Spontaneous Localisation Rates Implied by a Maximum Density: A Computed Bound and Laboratory Comparison

This paper computes what a maximum mass density implies for the collapse rate in continuous spontaneous localisation models and compares the outcome with laboratory limits. The density ceiling adopted here is 9.717e+57 kilograms per cubic metre on the neutron branch. Translating the ceiling into an energy budget over a Hubble time gives a formal upper value for the collapse rate of 6.753e+57 per second, many orders of magnitude above both the conventional value of 1.00e-16 per second and the stronger value of 1.00e-08 per second sometimes advocated on phenomenological grounds. The associated heating at the conventional rate is only 2.973e-17 watts per kilogram. The ceiling therefore does not restrict the collapse rate within any range currently discussed; the binding restrictions remain the laboratory limits from spontaneous radiation and force-noise measurements, which are tighter by an enormous margin. The study is simulated and computed from stated assumptions; it is not a measurement.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-11
DOI
https://doi.org/10.5281/zenodo.24145180
Primary Topic
Quantum Mechanics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Continuous Spontaneous Localisation Rates Implied by a Maximum Density: A Computed Bound and Laboratory Comparison

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Quantum Mechanics and Applications
article

Continuous Spontaneous Localisation Rates Implied by a Maximum Density: A Computed Bound and Laboratory Comparison

William Alexander Aldred
article en

Abstract

This paper computes what a maximum mass density implies for the collapse rate in continuous spontaneous localisation models and compares the outcome with laboratory limits. The density ceiling adopted here is 9.717e+57 kilograms per cubic metre on the neutron branch. Translating the ceiling into an energy budget over a Hubble time gives a formal upper value for the collapse rate of 6.753e+57 per second, many orders of magnitude above both the conventional value of 1.00e-16 per second and the stronger value of 1.00e-08 per second sometimes advocated on phenomenological grounds. The associated heating at the conventional rate is only 2.973e-17 watts per kilogram. The ceiling therefore does not restrict the collapse rate within any range currently discussed; the binding restrictions remain the laboratory limits from spontaneous radiation and force-noise measurements, which are tighter by an enormous margin. The study is simulated and computed from stated assumptions; it is not a measurement.

Zenodo (CERN European Organization for Nuclear Research)
Quantum Mechanics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon