Repeatability and Geometric Sensitivity of Digital Mandibular Displacement Measurements in Orthodontic Records

Digital mandibular displacement measurements require estimates of variability before small differences can be interpreted. In this secondary methodological analysis, we assessed the same-examiner agreement of stored digital centric-relation–maximum-intercuspation (CR–MIP) measurements and examined defined geometric sensitivities. Four anterior mandibular sites were measured twice, two weeks apart, by the same examiner using stored records from 14 patients in a doctoral cohort. The principal summary was the four-site mean. Analyses included an absolute-agreement intraclass correlation coefficient, ICC(A,1), patient-level bootstrap confidence intervals, Bland–Altman limits of agreement, standard error of measurement (SEM), and minimal detectable change (MDC95). Separate rigid-body calculations examined axis translation, closure to first contact, and landmark correspondence. Session means were 1.473 and 1.421 mm; ICC(A,1) was 0.915 (95% confidence interval, 0.761–0.972), bias −0.052 mm, SEM 0.238 mm, MDC95 0.661 mm, and limits of agreement −0.713 to 0.609 mm. At a retained 3° closure angle, a specified 5 mm perpendicular axis offset produced a calculated point-position change of 0.262 mm. Recalculating first contact could alter the closure angle and active contact. High relative reliability coexisted with appreciable absolute variation. Whether closure and landmark selection were repeated was undocumented; the estimates therefore do not establish repeatability of the complete measurement procedure, clinical accuracy or full-workflow reproducibility.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-11-11
DOI
https://doi.org/10.3390/app162211151
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Repeatability and Geometric Sensitivity of Digital Mandibular Displacement Measurements in Orthodontic Records

K Stefański, Renata Samulak, Rafał Rakoczy, Monika Machoy-Rakoczy et al.
Applied Sciences
Orthodontics and Dentofacial Orthopedics
article

Repeatability and Geometric Sensitivity of Digital Mandibular Displacement Measurements in Orthodontic Records

K Stefański, Renata Samulak, Rafał Rakoczy, Monika Machoy-Rakoczy, Nanxi Tao
article en

Abstract

Digital mandibular displacement measurements require estimates of variability before small differences can be interpreted. In this secondary methodological analysis, we assessed the same-examiner agreement of stored digital centric-relation–maximum-intercuspation (CR–MIP) measurements and examined defined geometric sensitivities. Four anterior mandibular sites were measured twice, two weeks apart, by the same examiner using stored records from 14 patients in a doctoral cohort. The principal summary was the four-site mean. Analyses included an absolute-agreement intraclass correlation coefficient, ICC(A,1), patient-level bootstrap confidence intervals, Bland–Altman limits of agreement, standard error of measurement (SEM), and minimal detectable change (MDC95). Separate rigid-body calculations examined axis translation, closure to first contact, and landmark correspondence. Session means were 1.473 and 1.421 mm; ICC(A,1) was 0.915 (95% confidence interval, 0.761–0.972), bias −0.052 mm, SEM 0.238 mm, MDC95 0.661 mm, and limits of agreement −0.713 to 0.609 mm. At a retained 3° closure angle, a specified 5 mm perpendicular axis offset produced a calculated point-position change of 0.262 mm. Recalculating first contact could alter the closure angle and active contact. High relative reliability coexisted with appreciable absolute variation. Whether closure and landmark selection were repeated was undocumented; the estimates therefore do not establish repeatability of the complete measurement procedure, clinical accuracy or full-workflow reproducibility.

Applied SciencesVol. 16(22)
West Pomeranian University of Technology in Szczecin (PL), Pomeranian Medical University (PL)
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Repeatability and Geometric Sensitivity of Digital Mandibular Displacement Measurements in Orthodontic Records — K Stefański, Renata Samulak, et al. · Applied Sciences (2026) | TGRS Research Map | TGRS