Dual-Time-Point Diagnostic 18F-FDG PET/MRI with 3-hour Delayed, Prone, Breast-Coil Acquisition for Characterization of BI-RADS 4 Nodules: A Single-Centre Diagnostic Accuracy Study

Abstract Objective Conventional PET/MRI often misclassifies BI-RADS 4 breast nodules because of high parenchymal metabolic background, coil-related ADC distortion and missed low-grade cancers. To evaluate the diagnostic performance of a combined multi-sequence dual-phase modular scanning (MSDP-MS) dataset integrating 3-h delayed 18 F-FDG PET with prone dedicated-breast-coil MRI, compared with early-phase supine-coil PET/MRI in BI-RADS 4 breast nodules. Subjects and methods: 68 women with BI-RADS 4 breast nodules were enrolled and underwent PET/MRI examinations from July 2020 to February 2025. All examinations were performed on a GE SIGNA 3.0 T integrated PET/MRI system. Image post-processing was performed on an AW 4.6 workstation. After 18 F-FDG injection, patients rested in a dim quiet room. Whole-body supine PET/MRI was performed using a 16-channel torso coil. PET acquisition duration was 8 min and total whole-body scan duration was 40 min. At approximately 3 h post-injection, a delayed targeted acquisition was performed for suspected nodules and metabolically- active lesions. The patient was positioned prone, with breasts placed within an 8- channel dedicated breast coil. PET acquisition lasted 8 min and additional MRI sequences added approximately 12 min of table-time. Two breast radiologists independently interpreted lesion findings, with histopathology serving as the reference standard. Results Among the 68 lesions, 24 were malignant and 44 were benign. Compared with early-only conventional PET/MRI, the combined MSDP-MS dataset yielded accuracy 941 % vs 824 % (P = 0.025), sensitivity 917 % vs 750 % (P = 0.041), specificity 955 % vs 864 % (P = 0.108). Malignant lesions demonstrated lower ADCmin values irrespective of 18 F-FDG uptake trend. Exploratory optimal subgroup-specific ADCmin thresholds were 0.86 × 10⁻³ mm²/s (SUV-increase subgroup) and 1.31 × 10⁻³ mm²/s (SUV-decrease subgroup). The additional delayed-phase imaging component added approximately 12 min of scanner table-time and improved overall diagnostic accuracyby 11.8 %, raising sensitivityto 91.7 %. Conclusion The combined MSDP-MS multiparametric dataset showed promising diagnostic performance for differentiating benign from malignant BI-RADS 4 breast nodules.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-11
DOI
https://doi.org/10.21203/rs.3.rs-11311013/v1
Primary Topic
Breast Lesions and Carcinomas
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Dual-Time-Point Diagnostic 18F-FDG PET/MRI with 3-hour Delayed, Prone, Breast-Coil Acquisition for Characterization of BI-RADS 4 Nodules: A Single-Centre Diagnostic Accuracy Study

史浩, Rui Xu, Yong Fu Su, Peng Yun Shi
Research Square
Breast Lesions and Carcinomas
preprint

Dual-Time-Point Diagnostic 18F-FDG PET/MRI with 3-hour Delayed, Prone, Breast-Coil Acquisition for Characterization of BI-RADS 4 Nodules: A Single-Centre Diagnostic Accuracy Study

史浩, Rui Xu, Yong Fu Su, Peng Yun Shi
preprint en

Abstract

Abstract Objective Conventional PET/MRI often misclassifies BI-RADS 4 breast nodules because of high parenchymal metabolic background, coil-related ADC distortion and missed low-grade cancers. To evaluate the diagnostic performance of a combined multi-sequence dual-phase modular scanning (MSDP-MS) dataset integrating 3-h delayed 18 F-FDG PET with prone dedicated-breast-coil MRI, compared with early-phase supine-coil PET/MRI in BI-RADS 4 breast nodules. Subjects and methods: 68 women with BI-RADS 4 breast nodules were enrolled and underwent PET/MRI examinations from July 2020 to February 2025. All examinations were performed on a GE SIGNA 3.0 T integrated PET/MRI system. Image post-processing was performed on an AW 4.6 workstation. After 18 F-FDG injection, patients rested in a dim quiet room. Whole-body supine PET/MRI was performed using a 16-channel torso coil. PET acquisition duration was 8 min and total whole-body scan duration was 40 min. At approximately 3 h post-injection, a delayed targeted acquisition was performed for suspected nodules and metabolically- active lesions. The patient was positioned prone, with breasts placed within an 8- channel dedicated breast coil. PET acquisition lasted 8 min and additional MRI sequences added approximately 12 min of table-time. Two breast radiologists independently interpreted lesion findings, with histopathology serving as the reference standard. Results Among the 68 lesions, 24 were malignant and 44 were benign. Compared with early-only conventional PET/MRI, the combined MSDP-MS dataset yielded accuracy 941 % vs 824 % (P = 0.025), sensitivity 917 % vs 750 % (P = 0.041), specificity 955 % vs 864 % (P = 0.108). Malignant lesions demonstrated lower ADCmin values irrespective of 18 F-FDG uptake trend. Exploratory optimal subgroup-specific ADCmin thresholds were 0.86 × 10⁻³ mm²/s (SUV-increase subgroup) and 1.31 × 10⁻³ mm²/s (SUV-decrease subgroup). The additional delayed-phase imaging component added approximately 12 min of scanner table-time and improved overall diagnostic accuracyby 11.8 %, raising sensitivityto 91.7 %. Conclusion The combined MSDP-MS multiparametric dataset showed promising diagnostic performance for differentiating benign from malignant BI-RADS 4 breast nodules.

Research Square
Qingdao University (CN), Shandong First Medical University (CN), Sichuan Taikang Hospital (CN)
Breast Lesions and Carcinomas
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon