Diagnostic Feasibility and Physical Assessment of Lung CT Images Reconstructed From Ultra-Low-Dose Positioning Scan for Computer-Aided Nodule Detection

OBJECTIVE: To evaluate the diagnostic feasibility of computer-aided detection (CAD) of pulmonary nodules on CT images reconstructed from volumetric ultra-low-dose (ULD) positioning scans compared with standard-dose CT. METHODS: In this retrospective study, 160 adults with at least 1 pulmonary nodule underwent volumetric ULD positioning scans and standard-dose CT. One target nodule per patient was analyzed. CAD sensitivity was evaluated on 5-mm volumetric ULD positioning scans and 5-mm standard-dose CT according to nodule size, morphology, and malignancy. An additional analysis was performed using 1-mm volumetric ULD positioning scans, with 1-mm standard-dose CT serving as the reference standard. Physical image characteristics were assessed using phantoms. RESULTS: A total of 160 nodules (median size: 5 mm) were analyzed. CAD sensitivity was 71.3% (114/160) for 5-mm volumetric ULD positioning scans and 85.0% (136/160) for 5-mm standard-dose CT (P<0.01), with reduced sensitivity most apparent for small nodules. With 1-mm volumetric ULD positioning scans, sensitivity improved to 88.8% (142/160). However, noninferiority to reference 1-mm standard-dose CT was not demonstrated using a 15-percentage-point margin (P=0.084). The median estimated effective dose was 0.18 mSv for volumetric ULD positioning scans and 4.67 mSv for standard-dose CT. Phantom assessment showed lower spatial resolution and increased low-frequency noise for volumetric ULD positioning scans. CONCLUSION: Thinner-slice reconstruction improved CAD sensitivity on volumetric ULD positioning scans; however, noninferiority to standard-dose CT was not demonstrated. Further optimization of image quality and CAD performance is warranted.

Authors

Institutions

Publication Details

Journal
Journal of Computer Assisted Tomography
Published
2026-11-11
DOI
https://doi.org/10.1097/rct.0000000000001944
Primary Topic
Lung Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Diagnostic Feasibility and Physical Assessment of Lung CT Images Reconstructed From Ultra-Low-Dose Positioning Scan for Computer-Aided Nodule Detection

Shintaro Ichikawa, Hiroyuki Morisaka, Kaori Aoyagi, Junichi Sato et al.
Journal of Computer Assisted Tomography
Lung Cancer Diagnosis and Treatment
article

Diagnostic Feasibility and Physical Assessment of Lung CT Images Reconstructed From Ultra-Low-Dose Positioning Scan for Computer-Aided Nodule Detection

Shintaro Ichikawa, Hiroyuki Morisaka, Kaori Aoyagi, Junichi Sato, Tomomi Yato, Hiroaki Watanabe
article en

Abstract

OBJECTIVE: To evaluate the diagnostic feasibility of computer-aided detection (CAD) of pulmonary nodules on CT images reconstructed from volumetric ultra-low-dose (ULD) positioning scans compared with standard-dose CT. METHODS: In this retrospective study, 160 adults with at least 1 pulmonary nodule underwent volumetric ULD positioning scans and standard-dose CT. One target nodule per patient was analyzed. CAD sensitivity was evaluated on 5-mm volumetric ULD positioning scans and 5-mm standard-dose CT according to nodule size, morphology, and malignancy. An additional analysis was performed using 1-mm volumetric ULD positioning scans, with 1-mm standard-dose CT serving as the reference standard. Physical image characteristics were assessed using phantoms. RESULTS: A total of 160 nodules (median size: 5 mm) were analyzed. CAD sensitivity was 71.3% (114/160) for 5-mm volumetric ULD positioning scans and 85.0% (136/160) for 5-mm standard-dose CT (P<0.01), with reduced sensitivity most apparent for small nodules. With 1-mm volumetric ULD positioning scans, sensitivity improved to 88.8% (142/160). However, noninferiority to reference 1-mm standard-dose CT was not demonstrated using a 15-percentage-point margin (P=0.084). The median estimated effective dose was 0.18 mSv for volumetric ULD positioning scans and 4.67 mSv for standard-dose CT. Phantom assessment showed lower spatial resolution and increased low-frequency noise for volumetric ULD positioning scans. CONCLUSION: Thinner-slice reconstruction improved CAD sensitivity on volumetric ULD positioning scans; however, noninferiority to standard-dose CT was not demonstrated. Further optimization of image quality and CAD performance is warranted.

Journal of Computer Assisted Tomography
University of Yamanashi Hospital (JP), University of Yamanashi (JP)
Lung Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon