Reproducible Laser-Induced Graphene Electrodes for Electrochemical Conductivity Sensing Enabled by Full Factorial Design of Experiments

Abstract Laser-induced graphene (LIG) enables scalable fabrication of conductive carbon electrodes directly on polymer substrates, but variations in laser-processing conditions can affect electrode properties and sensing reliability. In this work, a full factorial design of experiments was used to investigate how laser power, scan speed, focus offset, and scan cycle number influence LIG fabrication and quantitative aqueous conductivity sensing. Sheet resistance was used to identify under-exposed, optimized, and over-exposed processing regimes. Representative conditions were further characterized using surface and quasi-cross-sectional scanning electron microscopy, Raman spectroscopy, dynamic water contact-angle measurements, and cyclic voltammetry. Optimized conditions produced continuous porous LIG layers approximately 25–27 µm thick, with lower sheet resistance, more uniform graphitic structure, larger apparent electroactive surface area, and more defined ferri/ferrocyanide redox responses. Dynamic contact-angle measurements also revealed processing-dependent wetting behavior. Optimized and non-optimized electrodes were then compared as functionalization-free conductivity sensors using broadband electrochemical impedance spectroscopy and equivalent-circuit fitting to isolate bulk solution resistance. Over 13.33–3740 µS cm⁻¹, the optimized electrode produced a log–log resistance–conductivity slope of −0.944, approaching the theoretical inverse relationship, with measurement-to-measurement and sensor-to-sensor relative standard deviations of 1.79% and 3.00%, respectively. These results establish a fabrication–structure–impedance–conductivity relationship for reproducible LIG-based conductivity sensing in aqueous environmental monitoring applications.

Authors

Institutions

Publication Details

Journal
ECS Sensors Plus
Published
2026-11-11
DOI
https://doi.org/10.1149/2754-2726/aec0b4
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Reproducible Laser-Induced Graphene Electrodes for Electrochemical Conductivity Sensing Enabled by Full Factorial Design of Experiments

Nihal Ahmed, Stephan Warnat, Michael Neubauer
ECS Sensors Plus
Electrochemical sensors and biosensors
article

Reproducible Laser-Induced Graphene Electrodes for Electrochemical Conductivity Sensing Enabled by Full Factorial Design of Experiments

Nihal Ahmed, Stephan Warnat, Michael Neubauer
article en

Abstract

Abstract Laser-induced graphene (LIG) enables scalable fabrication of conductive carbon electrodes directly on polymer substrates, but variations in laser-processing conditions can affect electrode properties and sensing reliability. In this work, a full factorial design of experiments was used to investigate how laser power, scan speed, focus offset, and scan cycle number influence LIG fabrication and quantitative aqueous conductivity sensing. Sheet resistance was used to identify under-exposed, optimized, and over-exposed processing regimes. Representative conditions were further characterized using surface and quasi-cross-sectional scanning electron microscopy, Raman spectroscopy, dynamic water contact-angle measurements, and cyclic voltammetry. Optimized conditions produced continuous porous LIG layers approximately 25–27 µm thick, with lower sheet resistance, more uniform graphitic structure, larger apparent electroactive surface area, and more defined ferri/ferrocyanide redox responses. Dynamic contact-angle measurements also revealed processing-dependent wetting behavior. Optimized and non-optimized electrodes were then compared as functionalization-free conductivity sensors using broadband electrochemical impedance spectroscopy and equivalent-circuit fitting to isolate bulk solution resistance. Over 13.33–3740 µS cm⁻¹, the optimized electrode produced a log–log resistance–conductivity slope of −0.944, approaching the theoretical inverse relationship, with measurement-to-measurement and sensor-to-sensor relative standard deviations of 1.79% and 3.00%, respectively. These results establish a fabrication–structure–impedance–conductivity relationship for reproducible LIG-based conductivity sensing in aqueous environmental monitoring applications.

ECS Sensors Plus
Montana State University (US)
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Reproducible Laser-Induced Graphene Electrodes for Electrochemical Conductivity Sensing Enabled by Full Factorial Design of Experiments — Nihal Ahmed, Stephan Warnat, et al. · ECS Sensors Plus (2026) | TGRS Research Map | TGRS