MorphSSF: a fast slope-sum adaptive-period dilation algorithm for photoplethysmography beat detection

Abstract Objective: Detecting heartbeats in photoplethysmography (PPG) underlies heart-rate, heart-rate-variability and arrhythmia analysis on wearable and clinical devices, and must be both efficient and accurate. Several accurate benchmark detectors, especially the multi-scale peak-and-trough family (MSPTD/MSPTDfast), rely on costly local-maxima scalograms; we seek a detector that improves the benchmark-wide speed–accuracy trade-off rather than merely accelerating one baseline. Approach: MorphSSF converts each PPG window to a slope-sum function (SSF), estimates the dominant pulse period from a band-limited autocorrelation, and selects candidates as fixed points of a period-matched running-maximum dilation on the SSF. This combines systolic-upstroke enhancement with adaptive period spacing using one-dimensional operations and no scalogram. We evaluate under identical conditions on seven datasets (544 recordings) with benchmark-wide rank tests, detector-specific exclusions and one-to-one matching. Separate fixed-point C and causal MATLAB variants are evaluated. Main results: MorphSSF has the best mean dataset F1 rank. Against MSPTDfast (v2), sensitivity tests favour MorphSSF on five datasets (including a zero median effect on CapnoBase); F1 is higher on MIMIC-test, MIMIC-train and PPG-DaLiA, while positive predictive value (PPV) is lower on WESAD. Both pooled and equal-dataset analyses favour MorphSSF in F1 against all eight baselines. MorphSSF is 3.05–218.18× faster than the eight baselines, including 3.23× faster than MSPTDfast (v2), based on median runtime ratios across recordings. All detectors receive the same prefiltered PPG input, with this shared filtering step excluded from runtime measurements. Significance: Period-adaptive detection on the slope-sum provides an efficient, scalogram-free approach to PPG beat detection.

Authors

Institutions

Publication Details

Journal
Physiological Measurement
Published
2026-11-11
DOI
https://doi.org/10.1088/1361-6579/aec110
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

MorphSSF: a fast slope-sum adaptive-period dilation algorithm for photoplethysmography beat detection

Scott Desai, Wei Shi
Physiological Measurement
Non-Invasive Vital Sign Monitoring
article

MorphSSF: a fast slope-sum adaptive-period dilation algorithm for photoplethysmography beat detection

Scott Desai, Wei Shi
article en

Abstract

Abstract Objective: Detecting heartbeats in photoplethysmography (PPG) underlies heart-rate, heart-rate-variability and arrhythmia analysis on wearable and clinical devices, and must be both efficient and accurate. Several accurate benchmark detectors, especially the multi-scale peak-and-trough family (MSPTD/MSPTDfast), rely on costly local-maxima scalograms; we seek a detector that improves the benchmark-wide speed–accuracy trade-off rather than merely accelerating one baseline. Approach: MorphSSF converts each PPG window to a slope-sum function (SSF), estimates the dominant pulse period from a band-limited autocorrelation, and selects candidates as fixed points of a period-matched running-maximum dilation on the SSF. This combines systolic-upstroke enhancement with adaptive period spacing using one-dimensional operations and no scalogram. We evaluate under identical conditions on seven datasets (544 recordings) with benchmark-wide rank tests, detector-specific exclusions and one-to-one matching. Separate fixed-point C and causal MATLAB variants are evaluated. Main results: MorphSSF has the best mean dataset F1 rank. Against MSPTDfast (v2), sensitivity tests favour MorphSSF on five datasets (including a zero median effect on CapnoBase); F1 is higher on MIMIC-test, MIMIC-train and PPG-DaLiA, while positive predictive value (PPV) is lower on WESAD. Both pooled and equal-dataset analyses favour MorphSSF in F1 against all eight baselines. MorphSSF is 3.05–218.18× faster than the eight baselines, including 3.23× faster than MSPTDfast (v2), based on median runtime ratios across recordings. All detectors receive the same prefiltered PPG input, with this shared filtering step excluded from runtime measurements. Significance: Period-adaptive detection on the slope-sum provides an efficient, scalogram-free approach to PPG beat detection.

Physiological Measurement
Carleton University (CA)
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
MorphSSF: a fast slope-sum adaptive-period dilation algorithm for photoplethysmography beat detection — Scott Desai, Wei Shi · Physiological Measurement (2026) | TGRS Research Map | TGRS