A small angle of shunting and detectable shunting inlet may predict successful exclusive transvenous closure of patent ductus arteriosus with a 3-year follow-up

Background The transvenous V-method simplifies transcatheter patent ductus arteriosus (PDA) closure compared with the arteriovenous (AV) method and retrograde transarterial coil occlusion, with fewer complications, but it carries variable failure rates. This study aimed to identify preoperative transthoracic echocardiography (TTE) predictors for V-method failure and establish a practical model to optimize procedural strategies. Methods A total of 403 consecutive patients undergoing transcatheter PDA closure in Fujian Medical University Union Hospital between October 2014 and July 2019 were retrospectively enrolled and randomly split to training ( n = 282) and internal validation ( n = 121) cohorts at a 7:3 ratio. LASSO regression was performed to screen independent predictors. Model performance was validated via ROC, calibration and decision curve analysis. All patients received standardized 3-year postoperative follow-up. Results Overall, 323 patients completed V-method closure, and 80 converted to the AV-method. The median age was 7 years (6 months-73 years) and an average PDA size of 4.43 mm (1.0mm–14.5 mm). Large shunt angle (defined as shunt beam–PDA inlet plane angle; A larger angle may indicate more perpendicular insertion to the pulmonary artery wall) and undetectable PDA shunting inlet on preoperative TTE were independent predictors of V-method failure. The dual-index model achieved excellent predictive performance with AUCs of 0.933 (training) and 0.910 (validation), along with favorable calibration and clinical net benefit. The optimal cut-off value for the model was defined as an undetectable PDA shunting inlet or a shunt angle > 81.61°, with a sensitivity of 89.5% and a specificity of 96.4%. At 3-year follow-up, no signal of excess harm was detected in either group. Conclusion A small angle of shunting and detectable shunting inlet by echocardiography may predict successful exclusive transvenous PDA closure. The 3-year follow-up suggested the safety and efficacy of the exclusive transvenous access.

Authors

Institutions

Publication Details

Journal
Frontiers in Cardiovascular Medicine
Published
2026-11-11
DOI
https://doi.org/10.3389/fcvm.2026.1977237
Primary Topic
Cardiovascular Conditions and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A small angle of shunting and detectable shunting inlet may predict successful exclusive transvenous closure of patent ductus arteriosus with a 3-year follow-up

Wan Hua Chen, Hua Chen, Hui Ying Zheng, Jun Fang et al.
Frontiers in Cardiovascular Medicine
Cardiovascular Conditions and Treatments
article

A small angle of shunting and detectable shunting inlet may predict successful exclusive transvenous closure of patent ductus arteriosus with a 3-year follow-up

Wan Hua Chen, Hua Chen, Hui Ying Zheng, Jun Fang, Xiao Ping Yan, Dan Qing Hu
article en

Abstract

Background The transvenous V-method simplifies transcatheter patent ductus arteriosus (PDA) closure compared with the arteriovenous (AV) method and retrograde transarterial coil occlusion, with fewer complications, but it carries variable failure rates. This study aimed to identify preoperative transthoracic echocardiography (TTE) predictors for V-method failure and establish a practical model to optimize procedural strategies. Methods A total of 403 consecutive patients undergoing transcatheter PDA closure in Fujian Medical University Union Hospital between October 2014 and July 2019 were retrospectively enrolled and randomly split to training ( n = 282) and internal validation ( n = 121) cohorts at a 7:3 ratio. LASSO regression was performed to screen independent predictors. Model performance was validated via ROC, calibration and decision curve analysis. All patients received standardized 3-year postoperative follow-up. Results Overall, 323 patients completed V-method closure, and 80 converted to the AV-method. The median age was 7 years (6 months-73 years) and an average PDA size of 4.43 mm (1.0mm–14.5 mm). Large shunt angle (defined as shunt beam–PDA inlet plane angle; A larger angle may indicate more perpendicular insertion to the pulmonary artery wall) and undetectable PDA shunting inlet on preoperative TTE were independent predictors of V-method failure. The dual-index model achieved excellent predictive performance with AUCs of 0.933 (training) and 0.910 (validation), along with favorable calibration and clinical net benefit. The optimal cut-off value for the model was defined as an undetectable PDA shunting inlet or a shunt angle > 81.61°, with a sensitivity of 89.5% and a specificity of 96.4%. At 3-year follow-up, no signal of excess harm was detected in either group. Conclusion A small angle of shunting and detectable shunting inlet by echocardiography may predict successful exclusive transvenous PDA closure. The 3-year follow-up suggested the safety and efficacy of the exclusive transvenous access.

Frontiers in Cardiovascular MedicineVol. 13
Fujian Medical University (CN), Union Hospital (CN)
Cardiovascular Conditions and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon