Evaluating Multimodal Vision Frontier Models for Grading Neuroforaminal Stenosis on Lumbar Spine MRIs

Study Design Diagnostic accuracy study. Objective To determine whether a general-purpose multimodal artificial intelligence (AI) model, Gemini 3 Pro, grades lumbar neuroforaminal stenosis on magnetic resonance imaging (MRI) in agreement with expert radiologists, particularly for severe stenosis, and whether a vertebral-level localizer overlay helps. Methods One hundred lumbar MRIs from the Radiological Society of North America (RSNA) 2024 Lumbar Spine Degenerative Classification Dataset, graded by expert radiologists, provided 1,000 foramina (five levels, both sides) labeled normal/mild, moderate, or severe. Sagittal and axial T2-weighted series were converted into short scrolling videos and submitted to the model with a structured grading prompt; no task-specific training was performed. The primary outcome was agreement with expert grades (linearly weighted Cohen’s kappa, κw); secondary outcomes were accuracy, severe-stenosis sensitivity, direction of errors, and the localizer effect. Results Agreement with expert grading was poor (κw 0.20, 95% confidence interval [CI] 0.14–0.26). Accuracy was 70.6% (95% CI 67.7–73.4) but reflected the 70.4% of foramina that were normal/mild. The model identified 17.9% of severe foramina (95% CI 8.9–30.4) and called 58.9% normal/mild. Errors were systematically toward undergrading (p < 0.001). The localizer did not improve accuracy (70.0% vs 70.6%, p = 0.590) and reduced severe sensitivity (3.6% vs 17.9%, p = 0.043). Conclusions Without task-specific training, a general-purpose AI model reached moderate accuracy only because most foramina were normal or mild; it missed most severe stenosis and systematically undergraded. In its current form this approach is unsuitable for screening, triage, operative decision-making, or independent report generation.

Authors

Institutions

Publication Details

Journal
Global Spine Journal
Published
2026-11-11
DOI
https://doi.org/10.1177/21925682261508040
Primary Topic
Artificial Intelligence in Healthcare and Education
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Evaluating Multimodal Vision Frontier Models for Grading Neuroforaminal Stenosis on Lumbar Spine MRIs

Ibrahim Hussain, Harry Gebhard, Roger Härtl, Galal Elsayed et al.
Global Spine Journal
Artificial Intelligence in Healthcare and Education
article

Evaluating Multimodal Vision Frontier Models for Grading Neuroforaminal Stenosis on Lumbar Spine MRIs

Ibrahim Hussain, Harry Gebhard, Roger Härtl, Galal Elsayed, Noel F. Manalil, Ayesha Akbar Waheed, Sohail Rajesh Daulat, Chiungwen D. Cheng, Ahmet Kartal
article en

Abstract

Study Design Diagnostic accuracy study. Objective To determine whether a general-purpose multimodal artificial intelligence (AI) model, Gemini 3 Pro, grades lumbar neuroforaminal stenosis on magnetic resonance imaging (MRI) in agreement with expert radiologists, particularly for severe stenosis, and whether a vertebral-level localizer overlay helps. Methods One hundred lumbar MRIs from the Radiological Society of North America (RSNA) 2024 Lumbar Spine Degenerative Classification Dataset, graded by expert radiologists, provided 1,000 foramina (five levels, both sides) labeled normal/mild, moderate, or severe. Sagittal and axial T2-weighted series were converted into short scrolling videos and submitted to the model with a structured grading prompt; no task-specific training was performed. The primary outcome was agreement with expert grades (linearly weighted Cohen’s kappa, κw); secondary outcomes were accuracy, severe-stenosis sensitivity, direction of errors, and the localizer effect. Results Agreement with expert grading was poor (κw 0.20, 95% confidence interval [CI] 0.14–0.26). Accuracy was 70.6% (95% CI 67.7–73.4) but reflected the 70.4% of foramina that were normal/mild. The model identified 17.9% of severe foramina (95% CI 8.9–30.4) and called 58.9% normal/mild. Errors were systematically toward undergrading (p < 0.001). The localizer did not improve accuracy (70.0% vs 70.6%, p = 0.590) and reduced severe sensitivity (3.6% vs 17.9%, p = 0.043). Conclusions Without task-specific training, a general-purpose AI model reached moderate accuracy only because most foramina were normal or mild; it missed most severe stenosis and systematically undergraded. In its current form this approach is unsuitable for screening, triage, operative decision-making, or independent report generation.

Global Spine Journal
University of Arizona (US), University of Pittsburgh (US), Medizinische Universität Lausitz - Carl Thiem (DE), Weill Cornell Medicine (US)
Artificial Intelligence in Healthcare and Education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon