Design Blueprint: Sliding Door Bar

Design blueprint derived from the source paper (DOI 10.5281/zenodo.24121699): A length of timber dropped into the track of a sliding patio door is among the cheapest security devices sold, and among the least specified: dowels are bought by eye, in diameters that vary by a factor of two. This study computes the buckling load of a 0.9 m pine dowel from the Euler relation with a stated elastic modulus of 9 GPa, and compares it with a stated forcing load of 2,600 N at which the door's rollers and track begin to deform. A 25 mm dowel buckles at 2103 N, below the forcing load, so the door's own hardware is not the weakest element; the bar is. The buckling load reaches 2,600 Status: DESIGN BLUEPRINT — SIMULATED, NOT MEASURED — NOT BUILT. All numbers are simulated values from the source paper's computation, deposited with this blueprint as compute.py and results.json. AI-use disclosure: Dave, an AI research system, assisted with the computation and drafting under the author's direction; author of record William Alexander Aldred.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-11
DOI
https://doi.org/10.5281/zenodo.24122193
Primary Topic
Construction Engineering and Safety
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Design Blueprint: Sliding Door Bar

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Construction Engineering and Safety
article

Design Blueprint: Sliding Door Bar

William Alexander Aldred
article en

Abstract

Design blueprint derived from the source paper (DOI 10.5281/zenodo.24121699): A length of timber dropped into the track of a sliding patio door is among the cheapest security devices sold, and among the least specified: dowels are bought by eye, in diameters that vary by a factor of two. This study computes the buckling load of a 0.9 m pine dowel from the Euler relation with a stated elastic modulus of 9 GPa, and compares it with a stated forcing load of 2,600 N at which the door's rollers and track begin to deform. A 25 mm dowel buckles at 2103 N, below the forcing load, so the door's own hardware is not the weakest element; the bar is. The buckling load reaches 2,600 Status: DESIGN BLUEPRINT — SIMULATED, NOT MEASURED — NOT BUILT. All numbers are simulated values from the source paper's computation, deposited with this blueprint as compute.py and results.json. AI-use disclosure: Dave, an AI research system, assisted with the computation and drafting under the author's direction; author of record William Alexander Aldred.

Zenodo (CERN European Organization for Nuclear Research)
Construction Engineering and Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon