Optomechanical Force Noise and the Detectability of a Torsion-Induced Vacuum Force

This paper examines whether cryogenic optomechanical force sensitivity is sufficient to resolve vacuum forces at micrometre separations and limit an additional torsion-related component. The system considered is a picogram-scale cryogenic optomechanical resonator at 10 millikelvin, and the observable is thermal force noise, Casimir force magnitude and integration time. Evaluating the ordinary behaviour of the system and the spin-torsion contribution under explicit assumptions about polarisation and uniformity, and inverting the comparison at the stated laboratory precision, gives a quantitative bound rather than a qualitative assertion of smallness. The computed record is: force_noise_N_per_sqrtHz = 5.891e-20; casimir_force_N = 1.300e-11; integration_s_for_casimir_snr1 = 2.053e-17; mass_kg = 1.000e-12; temperature_K = 0.01. The torsion-related contribution is far below the level that would alter the ordinary behaviour of the system at current precision, and the value that would have produced a visible residual is stated so that future improvements can be assessed against it directly. No new measurement is reported. This study is simulated and computed from stated assumptions, not measured.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-11
DOI
https://doi.org/10.5281/zenodo.24133893
Primary Topic
Quantum Electrodynamics and Casimir Effect
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Optomechanical Force Noise and the Detectability of a Torsion-Induced Vacuum Force

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Quantum Electrodynamics and Casimir Effect
article

Optomechanical Force Noise and the Detectability of a Torsion-Induced Vacuum Force

William Alexander Aldred
article en

Abstract

This paper examines whether cryogenic optomechanical force sensitivity is sufficient to resolve vacuum forces at micrometre separations and limit an additional torsion-related component. The system considered is a picogram-scale cryogenic optomechanical resonator at 10 millikelvin, and the observable is thermal force noise, Casimir force magnitude and integration time. Evaluating the ordinary behaviour of the system and the spin-torsion contribution under explicit assumptions about polarisation and uniformity, and inverting the comparison at the stated laboratory precision, gives a quantitative bound rather than a qualitative assertion of smallness. The computed record is: force_noise_N_per_sqrtHz = 5.891e-20; casimir_force_N = 1.300e-11; integration_s_for_casimir_snr1 = 2.053e-17; mass_kg = 1.000e-12; temperature_K = 0.01. The torsion-related contribution is far below the level that would alter the ordinary behaviour of the system at current precision, and the value that would have produced a visible residual is stated so that future improvements can be assessed against it directly. No new measurement is reported. This study is simulated and computed from stated assumptions, not measured.

Zenodo (CERN European Organization for Nuclear Research)
Quantum Electrodynamics and Casimir Effect
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon