Monte Carlo Simulation of Energy Deposition in TF-1 and PbWO 4 Crystals Using Geant4

Using Geant4 Monte Carlo simulations, we study the interaction of a 20 MeV electron beam with two calorimetric materials: TF-1 lead tungstate and PbWO 4 crystals. The depth- dependent energy deposition profiles are calculated using 0.1 mm scoring bins, which are combined into 1 mm bins for the plotted profiles, taking into account a Gaussian beam energy spread (2% FWHM) and a radial Gaussian profile. The results show a strong dependence of shower development on material density. PbWO 4 exhibits rapid energy deposition and a shorter penetration depth, while TF-1 demonstrates deeper penetration and a broader shower profile. These findings are consistent with electromagnetic shower theory and are relevant for calorimeter design and radiation studies.

Authors

Institutions

Publication Details

Journal
Armenian Journal of Physics
Published
2026-11-11
DOI
https://doi.org/10.54503/18291171-2026.19.4-142
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Monte Carlo Simulation of Energy Deposition in TF-1 and PbWO 4 Crystals Using Geant4

V. R. Tadevosyan, A. Mkrtchyan, N. Prazyan, A. Stepanyan et al.
Armenian Journal of Physics
Particle Detector Development and Performance
article

Monte Carlo Simulation of Energy Deposition in TF-1 and PbWO 4 Crystals Using Geant4

V. R. Tadevosyan, A. Mkrtchyan, N. Prazyan, A. Stepanyan, H. Mkrtchyan, D. D. Khurshudyan, A. Hakobyan
article en

Abstract

Using Geant4 Monte Carlo simulations, we study the interaction of a 20 MeV electron beam with two calorimetric materials: TF-1 lead tungstate and PbWO 4 crystals. The depth- dependent energy deposition profiles are calculated using 0.1 mm scoring bins, which are combined into 1 mm bins for the plotted profiles, taking into account a Gaussian beam energy spread (2% FWHM) and a radial Gaussian profile. The results show a strong dependence of shower development on material density. PbWO 4 exhibits rapid energy deposition and a shorter penetration depth, while TF-1 demonstrates deeper penetration and a broader shower profile. These findings are consistent with electromagnetic shower theory and are relevant for calorimeter design and radiation studies.

Armenian Journal of PhysicsVol. 19(4)
A. Alikhanyan National Laboratory (AM)
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon