Study on change in keratometric measurements following application of tear substitutes with varying viscosity in cataract patients

Background: Preoperative keratometry is crucial for accurate intraocular lens (IOL) power calculation during cataract surgery. Dry eye disease (DED) destabilizes the tear film, potentially altering corneal curvature, biometric accuracy, and postoperative refractive outcomes. Influence of artificial tear viscosity on transient corneal regularity warrants investigation. Objectives: To compare baseline keratometric values between normal and dry eyes, assess effect of artificial tears on corneal astigmatism, and evaluate whether drop viscosity influences astigmatic correction. Methodology: A prospective, randomized, observational study was conducted at A.J. Institute of Medical Sciences, Mangalore, from July 2024 to June 2025. Ninety cataract eyes (45 and 45 normal) were classified according to DEWS 2017 criteria. Participants received either high- or low-viscosity artificial tears. Keratometric Corneal astigmatism measured before instillation, at 30 seconds, 2 minutes, and 5 minutes afterward. Paired and unpaired t-tests were used for analysis. Results: Baseline astigmatism was higher in dry eyes than normal eyes (1.58 ± 1.06 D vs. 0.90 ± 1.05 D; p = 0.005). Following tear instillation, dry eyes demonstrated significant reductions of 0.33 D, 0.48 D, and 0.62 D at 30 seconds, 2 minutes, and 5 minutes, respectively (all p < 0.0001). Normal eyes showed minimal, nonsignificant changes. The baseline difference of 0.68 D decreased to 0.03 D at 5 minutes (p = 0.915). High-viscosity drops produced slightly greater reduction than low-viscosity drops (0.47 D vs. 0.43 D), although the difference was not statistically significant. Conclusion: Artificial tears significantly reduced corneal astigmatism in dry eyes, achieving values comparable to normal eyes within 5 minutes. Although high-viscosity drops showed a modest numerical advantage, viscosity did not significantly influence outcomes. Pre-biometry tear supplementation may improve keratometric reliability and IOL power calculation accuracy in cataract patients with DED.

Authors

Publication Details

Journal
International Journal of Medical Ophthalmology
Published
2026-11-11
DOI
https://doi.org/10.33545/26638266.2026.v8.i4a.90552
Primary Topic
Ocular Surface and Contact Lens
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Study on change in keratometric measurements following application of tear substitutes with varying viscosity in cataract patients

Sahana S Karanth, Akansha Shetty, Rajani Kadri, Ajay A. Kudva et al.
International Journal of Medical Ophthalmology
Ocular Surface and Contact Lens
article

Study on change in keratometric measurements following application of tear substitutes with varying viscosity in cataract patients

Sahana S Karanth, Akansha Shetty, Rajani Kadri, Ajay A. Kudva, Shrishari N Shetty, Madhu S Singh, Devika Parameshwar
article en

Abstract

Background: Preoperative keratometry is crucial for accurate intraocular lens (IOL) power calculation during cataract surgery. Dry eye disease (DED) destabilizes the tear film, potentially altering corneal curvature, biometric accuracy, and postoperative refractive outcomes. Influence of artificial tear viscosity on transient corneal regularity warrants investigation. Objectives: To compare baseline keratometric values between normal and dry eyes, assess effect of artificial tears on corneal astigmatism, and evaluate whether drop viscosity influences astigmatic correction. Methodology: A prospective, randomized, observational study was conducted at A.J. Institute of Medical Sciences, Mangalore, from July 2024 to June 2025. Ninety cataract eyes (45 and 45 normal) were classified according to DEWS 2017 criteria. Participants received either high- or low-viscosity artificial tears. Keratometric Corneal astigmatism measured before instillation, at 30 seconds, 2 minutes, and 5 minutes afterward. Paired and unpaired t-tests were used for analysis. Results: Baseline astigmatism was higher in dry eyes than normal eyes (1.58 ± 1.06 D vs. 0.90 ± 1.05 D; p = 0.005). Following tear instillation, dry eyes demonstrated significant reductions of 0.33 D, 0.48 D, and 0.62 D at 30 seconds, 2 minutes, and 5 minutes, respectively (all p < 0.0001). Normal eyes showed minimal, nonsignificant changes. The baseline difference of 0.68 D decreased to 0.03 D at 5 minutes (p = 0.915). High-viscosity drops produced slightly greater reduction than low-viscosity drops (0.47 D vs. 0.43 D), although the difference was not statistically significant. Conclusion: Artificial tears significantly reduced corneal astigmatism in dry eyes, achieving values comparable to normal eyes within 5 minutes. Although high-viscosity drops showed a modest numerical advantage, viscosity did not significantly influence outcomes. Pre-biometry tear supplementation may improve keratometric reliability and IOL power calculation accuracy in cataract patients with DED.

International Journal of Medical OphthalmologyVol. 8(4)
Ocular Surface and Contact Lens
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon