An exploratory study on the influence of CT slice spacing on the positioning accuracy of 3D-printed patient-specific instruments designed for a distal radius osteotomy

Abstract Background Computed tomography (CT) images with slice spacing up to 3 mm are generally sufficient for accurate 3D reconstructions of patient anatomy. For designing patient-specific instruments, particularly for forearm and wrist osteotomies, higher-resolution imaging (slice spacing of 0.4–1.25 mm) is commonly used. However, it remains unclear whether CT slice spacing meaningfully affects the surface fit of 3D-printed patient-specific instruments. This in-vitro study quantified the impact of CT slice spacing on the positional accuracy of instruments for the distal radius. Methods Data from 12 patients were analysed. Each had a high-resolution CT image (0.625 mm slice spacing), from which a reference 3D radius model and a patient-specific instrument were designed. The original images were downsampled to slice spacings of 1.0, 1.25, 1.5, 1.875, and 2.5 mm to generate corresponding radius models and instrument bases. An experienced hand surgeon, blinded to slice spacing, fixated each 3D-printed instrument base onto its reference 3D-printed radius model in a simulated surgery. The assembled constructs were scanned, and the translation and rotation deviations of each lower-resolution instrument position were measured relative to the gold-standard instrument from the original scan. Results Mean rotational deviations across all slice spacings remained consistently low (< 1°), with the largest of 0.56° around the Z-axis at 2.5 mm. Translational deviations were similarly small (< 0.2 mm), with the greatest mean deviation of − 0.14 mm along the Z-axis at 1 mm. No systematic trend toward increasing error with decreasing image resolution was observed. Conclusion CT slice spacing had a generally small effect on the positional accuracy of 3D-printed patient-specific instruments for the distal radius in vitro. These results indicate that clinically acceptable instrument accuracy may be achieved across a broad range of CT slice spacing commonly used in musculoskeletal imaging, potentially reducing the need for high-resolution protocols in selected clinical scenarios.

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedic Surgery and Research
Published
2026-11-11
DOI
https://doi.org/10.1186/s13018-026-07374-2
Primary Topic
Anatomy and Medical Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

An exploratory study on the influence of CT slice spacing on the positioning accuracy of 3D-printed patient-specific instruments designed for a distal radius osteotomy

Anders Björkman, Peter Axelsson, Emilia Agnieszka Gryska, Katleen Libberecht et al.
Journal of Orthopaedic Surgery and Research
Anatomy and Medical Technology
article

An exploratory study on the influence of CT slice spacing on the positioning accuracy of 3D-printed patient-specific instruments designed for a distal radius osteotomy

Anders Björkman, Peter Axelsson, Emilia Agnieszka Gryska, Katleen Libberecht, Charlotte Stor Swinkels
article en

Abstract

Abstract Background Computed tomography (CT) images with slice spacing up to 3 mm are generally sufficient for accurate 3D reconstructions of patient anatomy. For designing patient-specific instruments, particularly for forearm and wrist osteotomies, higher-resolution imaging (slice spacing of 0.4–1.25 mm) is commonly used. However, it remains unclear whether CT slice spacing meaningfully affects the surface fit of 3D-printed patient-specific instruments. This in-vitro study quantified the impact of CT slice spacing on the positional accuracy of instruments for the distal radius. Methods Data from 12 patients were analysed. Each had a high-resolution CT image (0.625 mm slice spacing), from which a reference 3D radius model and a patient-specific instrument were designed. The original images were downsampled to slice spacings of 1.0, 1.25, 1.5, 1.875, and 2.5 mm to generate corresponding radius models and instrument bases. An experienced hand surgeon, blinded to slice spacing, fixated each 3D-printed instrument base onto its reference 3D-printed radius model in a simulated surgery. The assembled constructs were scanned, and the translation and rotation deviations of each lower-resolution instrument position were measured relative to the gold-standard instrument from the original scan. Results Mean rotational deviations across all slice spacings remained consistently low (< 1°), with the largest of 0.56° around the Z-axis at 2.5 mm. Translational deviations were similarly small (< 0.2 mm), with the greatest mean deviation of − 0.14 mm along the Z-axis at 1 mm. No systematic trend toward increasing error with decreasing image resolution was observed. Conclusion CT slice spacing had a generally small effect on the positional accuracy of 3D-printed patient-specific instruments for the distal radius in vitro. These results indicate that clinically acceptable instrument accuracy may be achieved across a broad range of CT slice spacing commonly used in musculoskeletal imaging, potentially reducing the need for high-resolution protocols in selected clinical scenarios.

Journal of Orthopaedic Surgery and ResearchVol. 21(1)
Sahlgrenska University Hospital (SE), University of Gothenburg (SE)
Anatomy and Medical Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon