Indoor Environmental Quality, Building-Related Symptoms and Perceived Productivity in Green-Certified and Conventional Tropical Offices

Abstract Although green building certification is widely promoted as a pathway to improved indoor environmental quality (IEQ) and occupant well-being, evidence of its effectiveness under tropical operating conditions remains limited and inconsistent. This study presents an integrated post-occupancy evaluation (POE) of indoor air quality (IAQ), occupant health, and workplace productivity across four office buildings in Colombo, Sri Lanka: two green-certified buildings (Buildings B and D) and two conventional buildings (Buildings A and C); the four buildings were broadly comparable in use but differed in age, size, occupancy, and HVAC configuration (Section 2.2). This exploratory, short-term (two-day per building) post-occupancy evaluation is intended as case-based screening evidence rather than a definitive assessment of green-building certification. Multi-parameter environmental monitoring (CO2, PM2.5/PM10, TVOC, formaldehyde, temperature, relative humidity, illuminance, and noise) was combined with a survey of 100 occupants covering thermal, air-quality, lighting, and acoustic comfort, self-reported building-related symptoms (SBS), and perceived productivity. Certified buildings recorded lower CO2 concentrations than conventional buildings (707 vs 841 ppm; p.adj < .001; d = -1.10), but higher relative humidity (66.0% vs 53.4%; d = 1.57) and noise (59.7 vs 56.6 dB(A); d = 0.47). The SBS symptom index was higher in certified buildings (2.51 vs 2.00; p.adj < .001), while comfort was lower (3.67 vs 4.18; p.adj = .003). Perceived productivity correlated most strongly with comfort (r = 0.62), IAQ satisfaction (r = 0.55), and acoustic comfort (r = 0.51). These findings reveal a case-specific divergence in which favorable ventilation performance coexisted with less favorable thermal, acoustic, and occupant-health outcomes. Certification alone therefore did not correspond to better occupant experience. The results support climate-responsive refinement of tropical green-building certification through consideration of humidity and acoustic performance, pending confirmation in seasonally sampled building cohorts.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-11
DOI
https://doi.org/10.21203/rs.3.rs-11162093/v1
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Indoor Environmental Quality, Building-Related Symptoms and Perceived Productivity in Green-Certified and Conventional Tropical Offices

Guttila Yugantha Jayasinghe, RU Halwathura, T. Kariyawasam², N. P. Dananjana¹ et al.
Research Square
Indoor Air Quality and Microbial Exposure
preprint

Indoor Environmental Quality, Building-Related Symptoms and Perceived Productivity in Green-Certified and Conventional Tropical Offices

Guttila Yugantha Jayasinghe, RU Halwathura, T. Kariyawasam², N. P. Dananjana¹, R. Galagoda³
preprint en

Abstract

Abstract Although green building certification is widely promoted as a pathway to improved indoor environmental quality (IEQ) and occupant well-being, evidence of its effectiveness under tropical operating conditions remains limited and inconsistent. This study presents an integrated post-occupancy evaluation (POE) of indoor air quality (IAQ), occupant health, and workplace productivity across four office buildings in Colombo, Sri Lanka: two green-certified buildings (Buildings B and D) and two conventional buildings (Buildings A and C); the four buildings were broadly comparable in use but differed in age, size, occupancy, and HVAC configuration (Section 2.2). This exploratory, short-term (two-day per building) post-occupancy evaluation is intended as case-based screening evidence rather than a definitive assessment of green-building certification. Multi-parameter environmental monitoring (CO2, PM2.5/PM10, TVOC, formaldehyde, temperature, relative humidity, illuminance, and noise) was combined with a survey of 100 occupants covering thermal, air-quality, lighting, and acoustic comfort, self-reported building-related symptoms (SBS), and perceived productivity. Certified buildings recorded lower CO2 concentrations than conventional buildings (707 vs 841 ppm; p.adj < .001; d = -1.10), but higher relative humidity (66.0% vs 53.4%; d = 1.57) and noise (59.7 vs 56.6 dB(A); d = 0.47). The SBS symptom index was higher in certified buildings (2.51 vs 2.00; p.adj < .001), while comfort was lower (3.67 vs 4.18; p.adj = .003). Perceived productivity correlated most strongly with comfort (r = 0.62), IAQ satisfaction (r = 0.55), and acoustic comfort (r = 0.51). These findings reveal a case-specific divergence in which favorable ventilation performance coexisted with less favorable thermal, acoustic, and occupant-health outcomes. Certification alone therefore did not correspond to better occupant experience. The results support climate-responsive refinement of tropical green-building certification through consideration of humidity and acoustic performance, pending confirmation in seasonally sampled building cohorts.

Research Square
Kanazawa University (JP), University of Ruhuna (LK), University of Moratuwa (LK)
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon