Effect of anterior and posterior horn suture stiffness on the biomechanical performance of a medial meniscal prosthesis: a finite element analysis

Background Meniscal injury is a common musculoskeletal disease. An artificial meniscal prosthesis is an effective choice for replacing allograft transplantation of the meniscus; however, the best method of fixation is still controversial. This finite element study aims to investigate the biomechanical effect of various anterior and posterior horn suture stiffnesses on a medial meniscal prosthesis under different knee flexion angles. Methods A validated three-dimensional finite element model of a human knee joint was used. A medial meniscal prosthesis of polycarbonate urethane (PCU) material was implanted, and spring elements were used to simulate the anterior and posterior horn fixation sutures and four levels of stiffness (13, 25, 62, and 200 N/mm) to represent available suture materials in the clinic. Knee flexion angles of 0°, 30°, and 60° were applied with combined anterior tibial load (134 N), compressive load (1150 N), and internal rotation moment (4 Nm). Tensile force in the sutures, meniscus translation (medial–lateral and anterior–posterior), and meniscus tibial contact stresses were extracted and analyzed. Results Increasing the suture stiffness resulted in increased force in the anterior horn sutures and the force in posterior horn sutures being mainly influenced by joint loading and not by suture stiffness. At 60° flexion, posterior horn tensile forces (50.11–52.35 N) were about 3.4–4.1 times greater than anterior horn tensile forces, which indicated the posterior horn as the major load-bearing structure. Increasing suture stiffness progressively decreased the medial–lateral and anterior–posterior displacements of the medial meniscus, and the 200 N/mm group of suture stiffnesses most closely approximated native meniscal kinematics. Medial tibial cartilage contact stress decreased with the increase of suture stiffness. It was found that 200 N/mm of suture stiffness most closely simulated the contact stress of the native knee for most loading conditions. The lateral compartment was not influenced by medial suture stiffness changes. Conclusion Suture stiffness is key to the overall biomechanical performance of artificial menisci. Stiffer fixation (200 N/mm) reduces the translation of the medial meniscal and tibial cartilage contact stress and restores the load distribution.

Authors

Institutions

Publication Details

Journal
Frontiers in Bioengineering and Biotechnology
Published
2026-11-11
DOI
https://doi.org/10.3389/fbioe.2026.1973619
Primary Topic
Knee injuries and reconstruction techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Effect of anterior and posterior horn suture stiffness on the biomechanical performance of a medial meniscal prosthesis: a finite element analysis

Weihan Yu, Chaohua Fang, Xuejia Li, Xing Zhou et al.
Frontiers in Bioengineering and Biotechnology
Knee injuries and reconstruction techniques
article

Effect of anterior and posterior horn suture stiffness on the biomechanical performance of a medial meniscal prosthesis: a finite element analysis

Weihan Yu, Chaohua Fang, Xuejia Li, Xing Zhou, Yiming Chen
article en

Abstract

Background Meniscal injury is a common musculoskeletal disease. An artificial meniscal prosthesis is an effective choice for replacing allograft transplantation of the meniscus; however, the best method of fixation is still controversial. This finite element study aims to investigate the biomechanical effect of various anterior and posterior horn suture stiffnesses on a medial meniscal prosthesis under different knee flexion angles. Methods A validated three-dimensional finite element model of a human knee joint was used. A medial meniscal prosthesis of polycarbonate urethane (PCU) material was implanted, and spring elements were used to simulate the anterior and posterior horn fixation sutures and four levels of stiffness (13, 25, 62, and 200 N/mm) to represent available suture materials in the clinic. Knee flexion angles of 0°, 30°, and 60° were applied with combined anterior tibial load (134 N), compressive load (1150 N), and internal rotation moment (4 Nm). Tensile force in the sutures, meniscus translation (medial–lateral and anterior–posterior), and meniscus tibial contact stresses were extracted and analyzed. Results Increasing the suture stiffness resulted in increased force in the anterior horn sutures and the force in posterior horn sutures being mainly influenced by joint loading and not by suture stiffness. At 60° flexion, posterior horn tensile forces (50.11–52.35 N) were about 3.4–4.1 times greater than anterior horn tensile forces, which indicated the posterior horn as the major load-bearing structure. Increasing suture stiffness progressively decreased the medial–lateral and anterior–posterior displacements of the medial meniscus, and the 200 N/mm group of suture stiffnesses most closely approximated native meniscal kinematics. Medial tibial cartilage contact stress decreased with the increase of suture stiffness. It was found that 200 N/mm of suture stiffness most closely simulated the contact stress of the native knee for most loading conditions. The lateral compartment was not influenced by medial suture stiffness changes. Conclusion Suture stiffness is key to the overall biomechanical performance of artificial menisci. Stiffer fixation (200 N/mm) reduces the translation of the medial meniscal and tibial cartilage contact stress and restores the load distribution.

Frontiers in Bioengineering and BiotechnologyVol. 14
Shanghai Jiao Tong University (CN), Shanghai University of Traditional Chinese Medicine (CN), Yueyang Hospital (CN), Shanghai First People's Hospital (CN)
Knee injuries and reconstruction techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon