Entropy per Baryon Across a Torsion Bounce: The Size of the Adiabatic Violation in the Effective Description

The net fractional change in comoving entropy across the bounce is 0.0 at a peak density ratio of unity: in this effective description the entropy that leaves the bounce equals the entropy that entered, exactly, because the correction is a function of density alone and the trajectory retraces its densities. The transient deviation during the crossing is a different matter. At a peak ratio of 0.1 the comoving entropy computed from the effective density departs from its adiabatic value by at most 0.076; at a peak ratio of 0.5 the maximum departure is 0.405; and at a peak ratio of 1.0 it reaches 1.000. The entropy per baryon is therefore conserved across the event but not during it: midway through the bounce the effective bookkeeping assigns the radiation a substantially different entropy than the adiabatic value, and the assignment reverts as the density falls. The study is a computation from stated assumptions, performed by the accompanying script; it is simulated, not measured.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-11
DOI
https://doi.org/10.5281/zenodo.24123378
Primary Topic
Cosmology and Gravitation Theories
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Entropy per Baryon Across a Torsion Bounce: The Size of the Adiabatic Violation in the Effective Description

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Cosmology and Gravitation Theories
article

Entropy per Baryon Across a Torsion Bounce: The Size of the Adiabatic Violation in the Effective Description

William Alexander Aldred
article en

Abstract

The net fractional change in comoving entropy across the bounce is 0.0 at a peak density ratio of unity: in this effective description the entropy that leaves the bounce equals the entropy that entered, exactly, because the correction is a function of density alone and the trajectory retraces its densities. The transient deviation during the crossing is a different matter. At a peak ratio of 0.1 the comoving entropy computed from the effective density departs from its adiabatic value by at most 0.076; at a peak ratio of 0.5 the maximum departure is 0.405; and at a peak ratio of 1.0 it reaches 1.000. The entropy per baryon is therefore conserved across the event but not during it: midway through the bounce the effective bookkeeping assigns the radiation a substantially different entropy than the adiabatic value, and the assignment reverts as the density falls. The study is a computation from stated assumptions, performed by the accompanying script; it is simulated, not measured.

Zenodo (CERN European Organization for Nuclear Research)
Cosmology and Gravitation Theories
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon