A height-aware design framework for single-tuned mass dampers in seismic steel buildings

Abstract This study presents a height-aware engineering design framework for roof-mounted single-tuned mass dampers (STMDs) in multi-story steel buildings. Five three-dimensional steel models with 5, 10, 12, 15, and 20 stories were analyzed in ABAQUS/CAE under the Kobe and Loma Prieta earthquake records. A baseline assessment first applied the Sadek tuning procedure using a fixed 5% mass ratio to investigate the influence of building height. The resulting response trends were interpreted using natural periods, modal-mass participation, a higher-mode influence index, and a detuning indicator. The 12-story model yielded the largest baseline roof-displacement reductions, reaching 46.0% under Kobe and 21.0% under Loma Prieta, whereas the corresponding reductions for the 20-story model were 12.8% and 10.7%, respectively. A surrogate-based parametric design exploration was subsequently used to examine practical combinations of mass ratio, tuning ratio, and damping ratio within prescribed bounds. The surrogate exploration identified candidate parameter sets that substantially mitigated dynamic demands in low- and mid-rise structures; however, it failed to overcome the intrinsic modal-dispersion bottleneck in the 20-story frame. For that model, combining the STMD with shear walls or outer inverted-V bracing increased the roof-displacement reduction to 45.4–65.5%, depending on the earthquake record and lateral-resisting configuration. The proposed sequence height screening, parameter exploration, and hybrid-system assessment provide a structured design process for selecting the control strategy within the investigated building family. However, the control efficacy of standalone STMDs remains fundamentally limited in taller, flexible buildings due to higher-mode mass participation and nonlinear frequency detuning. The present findings are bound by the investigated prototype steel frames, uniform cross-sectional benchmark assumptions, fixed-base boundary conditions, and the selected ground motion records.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-11-11
DOI
https://doi.org/10.1038/s41598-026-74894-6
Primary Topic
Vibration Control and Rheological Fluids
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A height-aware design framework for single-tuned mass dampers in seismic steel buildings

Mohamed S. Zahran, Yasser A. Khalifa, Hassan M. Farag, Mohamed M. Shabib
Scientific Reports
Vibration Control and Rheological Fluids
article

A height-aware design framework for single-tuned mass dampers in seismic steel buildings

Mohamed S. Zahran, Yasser A. Khalifa, Hassan M. Farag, Mohamed M. Shabib
article en

Abstract

Abstract This study presents a height-aware engineering design framework for roof-mounted single-tuned mass dampers (STMDs) in multi-story steel buildings. Five three-dimensional steel models with 5, 10, 12, 15, and 20 stories were analyzed in ABAQUS/CAE under the Kobe and Loma Prieta earthquake records. A baseline assessment first applied the Sadek tuning procedure using a fixed 5% mass ratio to investigate the influence of building height. The resulting response trends were interpreted using natural periods, modal-mass participation, a higher-mode influence index, and a detuning indicator. The 12-story model yielded the largest baseline roof-displacement reductions, reaching 46.0% under Kobe and 21.0% under Loma Prieta, whereas the corresponding reductions for the 20-story model were 12.8% and 10.7%, respectively. A surrogate-based parametric design exploration was subsequently used to examine practical combinations of mass ratio, tuning ratio, and damping ratio within prescribed bounds. The surrogate exploration identified candidate parameter sets that substantially mitigated dynamic demands in low- and mid-rise structures; however, it failed to overcome the intrinsic modal-dispersion bottleneck in the 20-story frame. For that model, combining the STMD with shear walls or outer inverted-V bracing increased the roof-displacement reduction to 45.4–65.5%, depending on the earthquake record and lateral-resisting configuration. The proposed sequence height screening, parameter exploration, and hybrid-system assessment provide a structured design process for selecting the control strategy within the investigated building family. However, the control efficacy of standalone STMDs remains fundamentally limited in taller, flexible buildings due to higher-mode mass participation and nonlinear frequency detuning. The present findings are bound by the investigated prototype steel frames, uniform cross-sectional benchmark assumptions, fixed-base boundary conditions, and the selected ground motion records.

Scientific ReportsVol. 16(1)
Military Technical College (EG)
Vibration Control and Rheological Fluids
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon