An ultrasonic sensing system for colonic content discrimination in ostomy patients: Development and experimental validation

Background Enterostomy leads to excretion incontinence, complications, and impaired quality of life, while existing interventions lack colonic content sensing capabilities. Objective The aim of this validation-based study was to develop and evaluate the technical performance of a smart ultrasonic sensing system for discriminating colonic content states to improve ostomy management. Method A modified 2 MHz reflective ultrasonic sensing system was developed, integrating an ultrasonic probe, transceiver circuit, signal amplification module, single-chip microcomputer, RGBW LEDs, and a buzzer alarm. Functional testing was performed under three immersion conditions (non-immersed, semi-immersed, and fully immersed) in normal saline. Voltage thresholds were established in vitro using excised colonic segments from 20 Oryctolagus cuniculus ( O. cuniculus ), with voltage signals measured under four colonic content states (gaseous, solid, fluid, and empty). In vivo validation was then conducted in 20 O. cuniculus and 12 Canis lupus familiaris ( C. lupus familiaris ). Data were analyzed using one-way ANOVA with LSD post-hoc tests (SPSS 27.0, p < 0.05). System performance was evaluated by the concordance between LED and buzzer outputs and reference colonic content states. Results Voltage output increased progressively with immersion depth in normal saline: 343.85 ± 2.11 mV (non-immersed), 637.60 ± 8.01 mV (semi-immersed), and 943.35 ± 3.86 mV (full- immersed) ( p < 0.001). In vitro, distinct voltages were recorded across states: gaseous (257.12 ± 10.51 mV), solid (398.12 ± 32.33 mV), fluid (507.24 ± 25.01 mV), and empty (658.56 ± 14.85 mV) (all p < 0.001). In vivo, the system achieved 98.0% overall accuracy in O. cuniculus (392/400) and 97.0% in C. lupus familiaris (419/432), with the solid state showing the lowest accuracy. Conclusion This study developed an integrated ultrasonic sensing system for artificial anal plugs, which achieved high classification accuracy and can provide reliable real-time feedback on colonic content, demonstrating strong potential for artificial anal plugs.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2026-11-11
DOI
https://doi.org/10.1371/journal.pone.0361870
Primary Topic
Stoma care and complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

An ultrasonic sensing system for colonic content discrimination in ostomy patients: Development and experimental validation

Yongshi Tang, Shanjiao Zhong, Xiongbo Guo, Deng GuangFei et al.
PLoS ONE
Stoma care and complications
article

An ultrasonic sensing system for colonic content discrimination in ostomy patients: Development and experimental validation

Yongshi Tang, Shanjiao Zhong, Xiongbo Guo, Deng GuangFei, Yi Pan, Tianjun Huang, Hui An, Yan Li
article en

Abstract

Background Enterostomy leads to excretion incontinence, complications, and impaired quality of life, while existing interventions lack colonic content sensing capabilities. Objective The aim of this validation-based study was to develop and evaluate the technical performance of a smart ultrasonic sensing system for discriminating colonic content states to improve ostomy management. Method A modified 2 MHz reflective ultrasonic sensing system was developed, integrating an ultrasonic probe, transceiver circuit, signal amplification module, single-chip microcomputer, RGBW LEDs, and a buzzer alarm. Functional testing was performed under three immersion conditions (non-immersed, semi-immersed, and fully immersed) in normal saline. Voltage thresholds were established in vitro using excised colonic segments from 20 Oryctolagus cuniculus ( O. cuniculus ), with voltage signals measured under four colonic content states (gaseous, solid, fluid, and empty). In vivo validation was then conducted in 20 O. cuniculus and 12 Canis lupus familiaris ( C. lupus familiaris ). Data were analyzed using one-way ANOVA with LSD post-hoc tests (SPSS 27.0, p < 0.05). System performance was evaluated by the concordance between LED and buzzer outputs and reference colonic content states. Results Voltage output increased progressively with immersion depth in normal saline: 343.85 ± 2.11 mV (non-immersed), 637.60 ± 8.01 mV (semi-immersed), and 943.35 ± 3.86 mV (full- immersed) ( p < 0.001). In vitro, distinct voltages were recorded across states: gaseous (257.12 ± 10.51 mV), solid (398.12 ± 32.33 mV), fluid (507.24 ± 25.01 mV), and empty (658.56 ± 14.85 mV) (all p < 0.001). In vivo, the system achieved 98.0% overall accuracy in O. cuniculus (392/400) and 97.0% in C. lupus familiaris (419/432), with the solid state showing the lowest accuracy. Conclusion This study developed an integrated ultrasonic sensing system for artificial anal plugs, which achieved high classification accuracy and can provide reliable real-time feedback on colonic content, demonstrating strong potential for artificial anal plugs.

PLoS ONEVol. 21(11)
Second Affiliated Hospital of Guangzhou Medical University (CN), Guangzhou Medical University (CN)
Stoma care and complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon