Complement C5b-9 membrane attack complex as a marker of severe preeclampsia

Aim : to assess diagnostic value for quantitating plasma and urinary levels of the membrane attack complex C5b-9 measured to discriminate severe from moderate preeclampsia (PE), to establish cut-off values and to examine their association with markers of organ dysfunction and coagulopathy. Materials and Methods . A prospective, controlled, observational, comparative, non-randomized, cross-sectional study enrolled 80 pregnant women: 50 with PE (21 moderate and 29 severe; 24 early-onset and 26 late-onset) and 30 healthy pregnant controls. Plasma and urinary C5b-9 were measured by enzyme-linked immunosorbent assay on the day of diagnosis. Diagnostic accuracy was evaluated using receiver operating characteristic (ROC) curve analysis; optimal cut-offs were selected by the Youden index. Results . Median [lower; upper quartile] C5b-9 levels were higher in severe vs. moderate PE: 1934.9 [1510.2; 2262.3] pg/mL vs. 314.0 [120.1; 757.4] pg/mL in plasma and 555.0 [364.0; 830.0] pg/mL vs. 119.3 [40.4; 224.3] pg/mL in urine (both p < 0.001), regardless of onset time. The area under the ROC curve for this parameter was 0.974 and 0.864 for plasma and urine samples, respectively. A plasma cut-off of ≥ 1042 pg/mL provided 93.1 % sensitivity and 100.0 % specificity, and a urinary cut-off of ≥ 250 pg/mL provided 89.7 % sensitivity and 81.0 % specificity. All severe cases exceeded at least one cut-off threshold. Higher C5b-9 levels were associated with lower platelet count, fibrinogen concentration and birth weight, while urinary C5b-9 correlated positively with lactate dehydrogenase and aspartate aminotransferase activity. Conclusion . Plasma and urinary C5b-9 measured at diagnosis accurately identify severe preeclampsia and reflect the degree of coagulopathy and organ injury. The proposed thresholds require external validation in multicentre studies using the same assay.

Authors

Institutions

Publication Details

Journal
Obstetrics Gynecology and Reproduction
Published
2026-11-11
DOI
https://doi.org/10.17749/2313-7347/ob.gyn.rep.2026.842
Primary Topic
Pregnancy and preeclampsia studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Complement C5b-9 membrane attack complex as a marker of severe preeclampsia

Irina M. Bogomazova, Тимохина Елена Владимировна, И.В. Игнатко, Irina A. Fedyunina et al.
Obstetrics Gynecology and Reproduction
Pregnancy and preeclampsia studies
article

Complement C5b-9 membrane attack complex as a marker of severe preeclampsia

Irina M. Bogomazova, Тимохина Елена Владимировна, И.В. Игнатко, Irina A. Fedyunina, M.A. Kardanova, Akhmedova A.E. Akhmedova
article en

Abstract

Aim : to assess diagnostic value for quantitating plasma and urinary levels of the membrane attack complex C5b-9 measured to discriminate severe from moderate preeclampsia (PE), to establish cut-off values and to examine their association with markers of organ dysfunction and coagulopathy. Materials and Methods . A prospective, controlled, observational, comparative, non-randomized, cross-sectional study enrolled 80 pregnant women: 50 with PE (21 moderate and 29 severe; 24 early-onset and 26 late-onset) and 30 healthy pregnant controls. Plasma and urinary C5b-9 were measured by enzyme-linked immunosorbent assay on the day of diagnosis. Diagnostic accuracy was evaluated using receiver operating characteristic (ROC) curve analysis; optimal cut-offs were selected by the Youden index. Results . Median [lower; upper quartile] C5b-9 levels were higher in severe vs. moderate PE: 1934.9 [1510.2; 2262.3] pg/mL vs. 314.0 [120.1; 757.4] pg/mL in plasma and 555.0 [364.0; 830.0] pg/mL vs. 119.3 [40.4; 224.3] pg/mL in urine (both p < 0.001), regardless of onset time. The area under the ROC curve for this parameter was 0.974 and 0.864 for plasma and urine samples, respectively. A plasma cut-off of ≥ 1042 pg/mL provided 93.1 % sensitivity and 100.0 % specificity, and a urinary cut-off of ≥ 250 pg/mL provided 89.7 % sensitivity and 81.0 % specificity. All severe cases exceeded at least one cut-off threshold. Higher C5b-9 levels were associated with lower platelet count, fibrinogen concentration and birth weight, while urinary C5b-9 correlated positively with lactate dehydrogenase and aspartate aminotransferase activity. Conclusion . Plasma and urinary C5b-9 measured at diagnosis accurately identify severe preeclampsia and reflect the degree of coagulopathy and organ injury. The proposed thresholds require external validation in multicentre studies using the same assay.

Obstetrics Gynecology and Reproduction
Sechenov University (RU), City Clinical Hospital (RU)
Pregnancy and preeclampsia studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon