MANAGEMENT OF MASSIVE ACETABULAR BONE DEFECTS IN REVISION HIP ARTHROPLASTY USING CUSTOM 3D-PRINTED IMPLANTS

Background: In repeat revision hip arthroplasty, acetabular component loosening, wear-induced osteolysis, and metallosis may be associated with extensive bone loss. Insufficient remaining bone stock compromises structural support and makes stable fixation with standard revision components challenging. Objective: To describe staged reconstruction of massive acetabular defects and the application of custom 3D-printed implants through two clinical cases. Clinical Cases and Methods: Two cases are presented: a 34-year-old man and a 38-year-old woman with a history of hip arthroplasty and repeated revision procedures. Component loosening was accompanied by metallosis and massive acetabular bone defects. The first treatment stage involved implant removal, excision of metallosis-affected periprosthetic soft tissue and bone, and temporary placement of antibiotic-loaded bone cement within the defect. Definitive reconstruction was planned as a separate stage. Computed tomography and three-dimensional modelling were used to assess defect geometry and remaining bone stock, identify implant–bone contact areas, and plan component orientation, the hip centre of rotation, and screw fixation trajectories. Reconstructive Principles: Patient-specific design allows the implant to accommodate the individual defect geometry and obtain fixation in better-preserved regions of host bone. The porous trabecular surface is intended to improve bone–implant interlock and, provided that reliable primary stability is achieved, support subsequent biological integration. Conclusion: Custom 3D-printed acetabular implants offer a reconstructive option for complex massive defects when adequate fixation with conventional components is limited. Accurate preoperative planning, reliable support on remaining host bone, and conditions conducive to osseointegration are central to this approach. Further clinical and radiographic follow-up is required to assess long-term effectiveness.

Authors

Publication Details

Journal
GEORGIAN SCIENTISTS
Published
2026-11-11
DOI
https://doi.org/10.52340/gs.2026.08.04(1).59
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

MANAGEMENT OF MASSIVE ACETABULAR BONE DEFECTS IN REVISION HIP ARTHROPLASTY USING CUSTOM 3D-PRINTED IMPLANTS

Giorgi Phutkaradze
GEORGIAN SCIENTISTS
Orthopaedic implants and arthroplasty
article

MANAGEMENT OF MASSIVE ACETABULAR BONE DEFECTS IN REVISION HIP ARTHROPLASTY USING CUSTOM 3D-PRINTED IMPLANTS

Giorgi Phutkaradze
article en

Abstract

Background: In repeat revision hip arthroplasty, acetabular component loosening, wear-induced osteolysis, and metallosis may be associated with extensive bone loss. Insufficient remaining bone stock compromises structural support and makes stable fixation with standard revision components challenging. Objective: To describe staged reconstruction of massive acetabular defects and the application of custom 3D-printed implants through two clinical cases. Clinical Cases and Methods: Two cases are presented: a 34-year-old man and a 38-year-old woman with a history of hip arthroplasty and repeated revision procedures. Component loosening was accompanied by metallosis and massive acetabular bone defects. The first treatment stage involved implant removal, excision of metallosis-affected periprosthetic soft tissue and bone, and temporary placement of antibiotic-loaded bone cement within the defect. Definitive reconstruction was planned as a separate stage. Computed tomography and three-dimensional modelling were used to assess defect geometry and remaining bone stock, identify implant–bone contact areas, and plan component orientation, the hip centre of rotation, and screw fixation trajectories. Reconstructive Principles: Patient-specific design allows the implant to accommodate the individual defect geometry and obtain fixation in better-preserved regions of host bone. The porous trabecular surface is intended to improve bone–implant interlock and, provided that reliable primary stability is achieved, support subsequent biological integration. Conclusion: Custom 3D-printed acetabular implants offer a reconstructive option for complex massive defects when adequate fixation with conventional components is limited. Accurate preoperative planning, reliable support on remaining host bone, and conditions conducive to osseointegration are central to this approach. Further clinical and radiographic follow-up is required to assess long-term effectiveness.

GEORGIAN SCIENTISTS
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon