A Vacuum-Gradient Energy Harvester: Casimir Stroke Work and Power at Micrometre Gaps

This paper presents a complete design study of a vacuum-gradient energy harvester that extracts stroke work from the Casimir attraction between conducting plates, computed throughout from stated assumptions and the standard pressure law. At a closed gap of 0.50 micrometres the net work is 1.38 nanojoules per cycle and the net power at the stated cycling rate is 1.38 microwatts for a plate array of one square metre. Closing the gap to 0.10 micrometres raises the net work per cycle to 173.34 nanojoules and the net power to 173.34 microwatts, while a 2.0 micrometre gap yields only 0.02 microwatts. The verdict of the arithmetic is that the device is sound and negligible. Every figure is a computed result of the stated model and nothing was built or tested: the study is SIMULATED, NOT MEASURED, and its limits are stated as plainly as its performance.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-11
DOI
https://doi.org/10.5281/zenodo.24125915
Citations
1
Primary Topic
Quantum Electrodynamics and Casimir Effect
Type
article
Field-Weighted Citation Impact
1.20
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Vacuum-Gradient Energy Harvester: Casimir Stroke Work and Power at Micrometre Gaps

William Alexander Aldred
1 citations
Zenodo (CERN European Organization for Nuclear Research)
Quantum Electrodynamics and Casimir Effect
1.20
article

A Vacuum-Gradient Energy Harvester: Casimir Stroke Work and Power at Micrometre Gaps

William Alexander Aldred
article en
1 citations

Abstract

This paper presents a complete design study of a vacuum-gradient energy harvester that extracts stroke work from the Casimir attraction between conducting plates, computed throughout from stated assumptions and the standard pressure law. At a closed gap of 0.50 micrometres the net work is 1.38 nanojoules per cycle and the net power at the stated cycling rate is 1.38 microwatts for a plate array of one square metre. Closing the gap to 0.10 micrometres raises the net work per cycle to 173.34 nanojoules and the net power to 173.34 microwatts, while a 2.0 micrometre gap yields only 0.02 microwatts. The verdict of the arithmetic is that the device is sound and negligible. Every figure is a computed result of the stated model and nothing was built or tested: the study is SIMULATED, NOT MEASURED, and its limits are stated as plainly as its performance.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 29%
Quantum Electrodynamics and Casimir Effect
1.20
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon