The use of high-resolution ct (HRCT) of the temporal bone for accurate preoperative prediction of stapes prosthesis length in patients with otosclerosis

Abstract Introduction Otosclerosis is managed surgically by stapedotomy or stapedectomy with the insertion of a stapes prosthesis. An ideal prosthesis length and accurate placement are crucial for good surgical and hearing outcomes. Methods This retrospective review was conducted on 179 ears diagnosed with otosclerosis that underwent stapes surgery at our institution between January 2014 and March 2023. Preoperative high–resolution computed tomography (HRCT) imaging of the temporal bone was used to measure the distance between the long process of the incus and the stapes footplate. The measurements were independently obtained by two otolaryngologists (observers 1 and 2) and a radiologist (observer 3). The actual measured and rounded values were analyzed and compared along with the inter-observer agreement for prosthesis length and accuracy predictability. Results The mean radiological distance measured from preoperative HRCT imaging was 4.25 mm (range = 4.1 to 4.4 mm). The interobserver agreement was moderately reliable between observer 1 and 2 (ICC 0.57; 95% CI: 0.43, 0.68); between observer 2 and 3 (ICC 0.58; 95% CI: 0.43, 0.68); between observer 3 and the actual length of prosthesis used (ICC 0.50; 95% CI: 0.32, 0.62). When measurements by the radiologist were rounded to the nearest 0.25 mm, 43% (78) of cases matched exactly with the prosthesis used intraoperatively, 22% ( n = 39) showed a value 0.25 mm higher, and 16% ( n = 29) showed a value 0.25 mm lower than the actual length of the prosthesis used. Conclusion Although radiological measurements from HRCT imaging cannot replace the current method of intraoperative measurement of stapes prosthesis length, when the measurement process is difficult, the values measured by a radiologist could be used to estimate the prosthesis length required.

Authors

Institutions

Publication Details

Journal
The Egyptian Journal of Otolaryngology
Published
2026-11-10
DOI
https://doi.org/10.1186/s43163-026-01267-1
Primary Topic
Ear Surgery and Otitis Media
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

The use of high-resolution ct (HRCT) of the temporal bone for accurate preoperative prediction of stapes prosthesis length in patients with otosclerosis

Soumya Susan Regi, Manju Deena Mammen, Ajay Philip, Neethu Sunil et al.
The Egyptian Journal of Otolaryngology
Ear Surgery and Otitis Media
article

The use of high-resolution ct (HRCT) of the temporal bone for accurate preoperative prediction of stapes prosthesis length in patients with otosclerosis

Soumya Susan Regi, Manju Deena Mammen, Ajay Philip, Neethu Sunil, Ann Mary Augustine, Anjana Juanita Job, Maya P. G.
article en

Abstract

Abstract Introduction Otosclerosis is managed surgically by stapedotomy or stapedectomy with the insertion of a stapes prosthesis. An ideal prosthesis length and accurate placement are crucial for good surgical and hearing outcomes. Methods This retrospective review was conducted on 179 ears diagnosed with otosclerosis that underwent stapes surgery at our institution between January 2014 and March 2023. Preoperative high–resolution computed tomography (HRCT) imaging of the temporal bone was used to measure the distance between the long process of the incus and the stapes footplate. The measurements were independently obtained by two otolaryngologists (observers 1 and 2) and a radiologist (observer 3). The actual measured and rounded values were analyzed and compared along with the inter-observer agreement for prosthesis length and accuracy predictability. Results The mean radiological distance measured from preoperative HRCT imaging was 4.25 mm (range = 4.1 to 4.4 mm). The interobserver agreement was moderately reliable between observer 1 and 2 (ICC 0.57; 95% CI: 0.43, 0.68); between observer 2 and 3 (ICC 0.58; 95% CI: 0.43, 0.68); between observer 3 and the actual length of prosthesis used (ICC 0.50; 95% CI: 0.32, 0.62). When measurements by the radiologist were rounded to the nearest 0.25 mm, 43% (78) of cases matched exactly with the prosthesis used intraoperatively, 22% ( n = 39) showed a value 0.25 mm higher, and 16% ( n = 29) showed a value 0.25 mm lower than the actual length of the prosthesis used. Conclusion Although radiological measurements from HRCT imaging cannot replace the current method of intraoperative measurement of stapes prosthesis length, when the measurement process is difficult, the values measured by a radiologist could be used to estimate the prosthesis length required.

The Egyptian Journal of OtolaryngologyVol. 42(1)
Christian Medical College, Vellore (IN)
Ear Surgery and Otitis Media
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon