Development and Preliminary Analytical Evaluation of a Portable Electronic-Nose Method for Discriminating Cassia grandis-Enriched Rice Beverages Using Chemometrics and HS-SPME-GC-MS

This study presents the development and preliminary analytical evaluation of a portable electronic nose (E-nose) for differentiating rice-based beverages containing 0, 5, 10, and 20% (w/v) Cassia grandis pulp. The system was evaluated through optimization of the operating conditions, assessment of short-term repeatability and robustness, exploratory chemometric analysis, and complementary volatile characterization by headspace solid-phase microextraction coupled with gas chromatography–mass spectrometry (HS-SPME-GC-MS). The optimized conditions comprised a sample volume of 20 mL, a headspace equilibration time of 10 min, an adsorption period of 60 s, and a desorption period of 30 s. Under these conditions, the sensor responses exhibited relative standard deviations (RSDs) ranging from 1.88 to 3.67% during ten consecutive measurements. Robustness experiments involving deliberate variations in the operating parameters yielded RSDs between 0.87 and 2.48%, although reducing the desorption time to 20 s decreased the mean sensor response by 5.29%. Three independent beverage preparations were produced for each formulation, and ten E-nose measurements were obtained per formulation, resulting in 40 instrumental measurements. Principal component analysis (PCA) accounted for 96.18% of the total variance in the first two components (PC1: 87.04%; PC2: 9.14%) and revealed differences in sensor-response patterns among formulations. The control (A0) and the formulation containing 20% C. grandis pulp (A20) occupied distinct regions of the PCA space, whereas A5 and A10 exhibited greater similarity. Complementary HS-SPME-GC-MS analysis revealed formulation-dependent differences in chromatographic peak areas, particularly for terpene-related compounds. For example, the linalool peak area increased from 18.34 × 106 in A0 to 535.50 × 106 arbitrary units in A20. Nevertheless, preparation-grouped cross-validation and independent predictive validation could not be established from the available experimental records.

Authors

Institutions

Publication Details

Journal
Chemosensors
Published
2026-11-10
DOI
https://doi.org/10.3390/chemosensors14110253
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Development and Preliminary Analytical Evaluation of a Portable Electronic-Nose Method for Discriminating Cassia grandis-Enriched Rice Beverages Using Chemometrics and HS-SPME-GC-MS

Daniel Martín‐Vertedor, Francisco Pérez Nevado, Ismael Montero-Fernández, Jesús Lozano et al.
Chemosensors
Advanced Chemical Sensor Technologies
article

Development and Preliminary Analytical Evaluation of a Portable Electronic-Nose Method for Discriminating Cassia grandis-Enriched Rice Beverages Using Chemometrics and HS-SPME-GC-MS

Daniel Martín‐Vertedor, Francisco Pérez Nevado, Ismael Montero-Fernández, Jesús Lozano, Víctor Manrique Fernández
article en

Abstract

This study presents the development and preliminary analytical evaluation of a portable electronic nose (E-nose) for differentiating rice-based beverages containing 0, 5, 10, and 20% (w/v) Cassia grandis pulp. The system was evaluated through optimization of the operating conditions, assessment of short-term repeatability and robustness, exploratory chemometric analysis, and complementary volatile characterization by headspace solid-phase microextraction coupled with gas chromatography–mass spectrometry (HS-SPME-GC-MS). The optimized conditions comprised a sample volume of 20 mL, a headspace equilibration time of 10 min, an adsorption period of 60 s, and a desorption period of 30 s. Under these conditions, the sensor responses exhibited relative standard deviations (RSDs) ranging from 1.88 to 3.67% during ten consecutive measurements. Robustness experiments involving deliberate variations in the operating parameters yielded RSDs between 0.87 and 2.48%, although reducing the desorption time to 20 s decreased the mean sensor response by 5.29%. Three independent beverage preparations were produced for each formulation, and ten E-nose measurements were obtained per formulation, resulting in 40 instrumental measurements. Principal component analysis (PCA) accounted for 96.18% of the total variance in the first two components (PC1: 87.04%; PC2: 9.14%) and revealed differences in sensor-response patterns among formulations. The control (A0) and the formulation containing 20% C. grandis pulp (A20) occupied distinct regions of the PCA space, whereas A5 and A10 exhibited greater similarity. Complementary HS-SPME-GC-MS analysis revealed formulation-dependent differences in chromatographic peak areas, particularly for terpene-related compounds. For example, the linalool peak area increased from 18.34 × 106 in A0 to 535.50 × 106 arbitrary units in A20. Nevertheless, preparation-grouped cross-validation and independent predictive validation could not be established from the available experimental records.

ChemosensorsVol. 14(11)
Government of Extremadura (ES), Universidad de Extremadura (ES)
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon