Serum GAS5, miR-320 and autophagy-related genes Beclin-1 and LC3 in coronary in-stent restenosis: Expression patterns and clinical correlations

Objective This study evaluated whether circulating GAS5, miR-320, Beclin-1, and LC3 are associated with angiographically confirmed in-stent restenosis (ISR) and its angiographic severity in patients after drug-eluting stent (DES) implantation. Methods In this retrospective matched observational study, 132 patients (60 ISR, 72 non-ISR) were stratified by coronary angiography within six months of PCI; 1:1 propensity score matching yielded 52 pairs (104 patients). Serum GAS5 and miR-320 (qRT-PCR) and Beclin-1 and LC3 (ELISA) were measured at baseline and at the six-month follow-up. Correlation, ROC, and regression analyses evaluated contemporaneous diagnostic accuracy and associations with ISR. Results After PSM, all SMDs were ≤ 0.27 (13 of 20 covariates < 0.10). ISR patients had higher GAS5, Beclin-1, and LC3 and lower miR-320 than non-ISR patients at both timepoints (all P < 0.001). All four biomarkers correlated with stenosis severity at both timepoints (Spearman |rs| = 0.25–0.60). Using six-month values obtained concurrently with angiography, the combined panel achieved an AUC of 0.88 (95% CI: 0.80–0.93), exceeding Beclin-1 and LC3 (both P < 0.01) and miR-320 (P = 0.041), with a non-significant trend versus GAS5 (P = 0.082). Lower miR-320 and higher Beclin-1 remained independently associated with ISR; conditional logistic regression confirmed miR-320 as the most robust marker (OR = 0.20 per SD, P = 0.023). Baseline (pre-PCI) analyses are reported separately as exploratory. Conclusion Serum GAS5, miR-320, Beclin-1, and LC3 are promising autophagy-related biomarkers for the contemporaneous discrimination of angiographically confirmed ISR, and combined detection improves diagnostic reliability. Because biomarkers and ISR were assessed at the same visit without longitudinal outcomes, these findings do not establish prospective prediction and require external validation.

Authors

Publication Details

Journal
Journal of Radiation Research and Applied Sciences
Published
2026-11-10
DOI
https://doi.org/10.1016/j.jrras.2026.102795
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Serum GAS5, miR-320 and autophagy-related genes Beclin-1 and LC3 in coronary in-stent restenosis: Expression patterns and clinical correlations

Rui Fan, Yulong Ma
Journal of Radiation Research and Applied Sciences
Coronary Interventions and Diagnostics
article

Serum GAS5, miR-320 and autophagy-related genes Beclin-1 and LC3 in coronary in-stent restenosis: Expression patterns and clinical correlations

Rui Fan, Yulong Ma
article en

Abstract

Objective This study evaluated whether circulating GAS5, miR-320, Beclin-1, and LC3 are associated with angiographically confirmed in-stent restenosis (ISR) and its angiographic severity in patients after drug-eluting stent (DES) implantation. Methods In this retrospective matched observational study, 132 patients (60 ISR, 72 non-ISR) were stratified by coronary angiography within six months of PCI; 1:1 propensity score matching yielded 52 pairs (104 patients). Serum GAS5 and miR-320 (qRT-PCR) and Beclin-1 and LC3 (ELISA) were measured at baseline and at the six-month follow-up. Correlation, ROC, and regression analyses evaluated contemporaneous diagnostic accuracy and associations with ISR. Results After PSM, all SMDs were ≤ 0.27 (13 of 20 covariates < 0.10). ISR patients had higher GAS5, Beclin-1, and LC3 and lower miR-320 than non-ISR patients at both timepoints (all P < 0.001). All four biomarkers correlated with stenosis severity at both timepoints (Spearman |rs| = 0.25–0.60). Using six-month values obtained concurrently with angiography, the combined panel achieved an AUC of 0.88 (95% CI: 0.80–0.93), exceeding Beclin-1 and LC3 (both P < 0.01) and miR-320 (P = 0.041), with a non-significant trend versus GAS5 (P = 0.082). Lower miR-320 and higher Beclin-1 remained independently associated with ISR; conditional logistic regression confirmed miR-320 as the most robust marker (OR = 0.20 per SD, P = 0.023). Baseline (pre-PCI) analyses are reported separately as exploratory. Conclusion Serum GAS5, miR-320, Beclin-1, and LC3 are promising autophagy-related biomarkers for the contemporaneous discrimination of angiographically confirmed ISR, and combined detection improves diagnostic reliability. Because biomarkers and ISR were assessed at the same visit without longitudinal outcomes, these findings do not establish prospective prediction and require external validation.

Journal of Radiation Research and Applied SciencesVol. 19(4)
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Serum GAS5, miR-320 and autophagy-related genes Beclin-1 and LC3 in coronary in-stent restenosis: Expression patterns and clinical correlations — Rui Fan, Yulong Ma · Journal of Radiation Research and Applied Sciences (2026) | TGRS Research Map | TGRS