Seismic Performance and Structural Capacity Assessment of a Ten-Story Reinforced Concrete Building Using Nonlinear Static Pushover Analysis

The seismic performance of reinforced concrete buildings depends on adequate member strength and the ability of the structural system to sustain lateral deformation beyond the elastic range. This study aims to assess the structural capacity and seismic performance of a ten-story reinforced concrete building through linear structural evaluation and nonlinear static pushover analysis. The assessment includes modal characteristics, mass participation, base reactions, interstory drift, beam and column capacity, pushover capacity curves, plastic-hinge development, and structural performance levels in the X and Y directions. Twelve vibration modes are considered, with cumulative translational mass participation reaching 94.13% in the X direction and 94.08% in the Y direction. The beam capacity evaluation gives a nominal flexural strength of 186.96 kN·m compared with a factored moment demand of 64.92 kN·m. The evaluated column has a reduced axial strength of 6407.29 kN against an axial demand of 1627.27 kN. Nonlinear static analysis shows that the maximum base shear reaches 17,110.19 kN at a roof displacement of 0.715 m in the X direction and 16,301.71 kN at 0.699 m in the Y direction. The X-direction lateral capacity is therefore approximately 5.0% higher than that in the Y direction. Plastic hinges progressively develop as lateral displacement increases, primarily within the lower and intermediate stories. The ATC-40 capacity-spectrum evaluation classifies the structural performance in both principal directions as Damage Control (SP-3), between Immediate Occupancy and Life Safety. The combined strength and nonlinear-response results indicate that the investigated building maintains adequate member capacity and lateral resistance at the evaluated seismic performance point, although the directional difference in stiffness and nonlinear response should be considered in the interpretation of its seismic behavior.

Authors

Institutions

Publication Details

Journal
Journal of Infrastructure and Civil Engineering
Published
2026-11-10
DOI
https://doi.org/10.35583/jice.v6i3.240
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Seismic Performance and Structural Capacity Assessment of a Ten-Story Reinforced Concrete Building Using Nonlinear Static Pushover Analysis

Wisnu Prayogo, Trimailuzi Trimailuzi, Cut Mutia Rani, Melvi Maulita Napitupulu et al.
Journal of Infrastructure and Civil Engineering
Seismic Performance and Analysis
article

Seismic Performance and Structural Capacity Assessment of a Ten-Story Reinforced Concrete Building Using Nonlinear Static Pushover Analysis

Wisnu Prayogo, Trimailuzi Trimailuzi, Cut Mutia Rani, Melvi Maulita Napitupulu, Khairunnisa Khairunnisa, Mena Fadillia Lukman
article en

Abstract

The seismic performance of reinforced concrete buildings depends on adequate member strength and the ability of the structural system to sustain lateral deformation beyond the elastic range. This study aims to assess the structural capacity and seismic performance of a ten-story reinforced concrete building through linear structural evaluation and nonlinear static pushover analysis. The assessment includes modal characteristics, mass participation, base reactions, interstory drift, beam and column capacity, pushover capacity curves, plastic-hinge development, and structural performance levels in the X and Y directions. Twelve vibration modes are considered, with cumulative translational mass participation reaching 94.13% in the X direction and 94.08% in the Y direction. The beam capacity evaluation gives a nominal flexural strength of 186.96 kN·m compared with a factored moment demand of 64.92 kN·m. The evaluated column has a reduced axial strength of 6407.29 kN against an axial demand of 1627.27 kN. Nonlinear static analysis shows that the maximum base shear reaches 17,110.19 kN at a roof displacement of 0.715 m in the X direction and 16,301.71 kN at 0.699 m in the Y direction. The X-direction lateral capacity is therefore approximately 5.0% higher than that in the Y direction. Plastic hinges progressively develop as lateral displacement increases, primarily within the lower and intermediate stories. The ATC-40 capacity-spectrum evaluation classifies the structural performance in both principal directions as Damage Control (SP-3), between Immediate Occupancy and Life Safety. The combined strength and nonlinear-response results indicate that the investigated building maintains adequate member capacity and lateral resistance at the evaluated seismic performance point, although the directional difference in stiffness and nonlinear response should be considered in the interpretation of its seismic behavior.

Journal of Infrastructure and Civil EngineeringVol. 6(3)
State University of Medan (ID)
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon