Roof Trusses from Poles: Geometry and Member Sizes for Spans from Four to Eight Metres

Where sawn timber is scarce or expensive, roof trusses are often built from round poles — and usually sized by copying whatever stood up last time. This paper originates a complete design method for one stated form, a king-post truss with two inclined struts at a 35 degree pitch and 3.0 m truss spacing, and computes its member sizes for spans from 4 to 8 m under two roof coverings. Member forces are obtained exactly, for the stated form, by solving joint equilibrium at all six joints simultaneously; members are then sized by stepping round-pole diameters upward until each passes an Euler buckling check with a safety factor of 3.0, an axial-plus-bending interaction check at stated allowable stresses for a stated pole class, and a joint check against stated pegged and lashed connection capacities. Under thatch (total stated load 0.90 kN/m² of slope) the lower rafter needs a diameter of 90 mm at 4 m span and 140 mm at 8 m; under tile (1.45 kN/m²) it needs 105 mm at 4 m and 165 mm at 8 m. The tie is never the problem: it requires only 60 to 90 mm across the whole range, and the king post passes at the 60 mm minimum diameter everywhere. Lashed joints, credited with a stated slip-limited capacity of 9.0 kN, suffice at every joint only for the 4 m thatch truss; everywhere else the primary joints need hardwood pegs, from 2 pegs at small spans to 4 pegs at the support of the 8 m tile truss. Extending the same method beyond the design range, the form stops working under tile between 9.0 m, which just passes with a 180 mm rafter, and 9.5 m, which no diameter up to the stated 180 mm maximum pole can carry; under thatch it stops between 11.5 and 12.0 m. In every failing case the lower rafter segment, in combined axial compression and bending, is the member that gives out — not the tie, not the king post, and not the joints. This study is simulated, not measured, and no truss described here has been load-tested.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-10
DOI
https://doi.org/10.5281/zenodo.24115350
Primary Topic
Structural Engineering and Materials Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Roof Trusses from Poles: Geometry and Member Sizes for Spans from Four to Eight Metres

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Structural Engineering and Materials Analysis
article

Roof Trusses from Poles: Geometry and Member Sizes for Spans from Four to Eight Metres

William Alexander Aldred
article en

Abstract

Where sawn timber is scarce or expensive, roof trusses are often built from round poles — and usually sized by copying whatever stood up last time. This paper originates a complete design method for one stated form, a king-post truss with two inclined struts at a 35 degree pitch and 3.0 m truss spacing, and computes its member sizes for spans from 4 to 8 m under two roof coverings. Member forces are obtained exactly, for the stated form, by solving joint equilibrium at all six joints simultaneously; members are then sized by stepping round-pole diameters upward until each passes an Euler buckling check with a safety factor of 3.0, an axial-plus-bending interaction check at stated allowable stresses for a stated pole class, and a joint check against stated pegged and lashed connection capacities. Under thatch (total stated load 0.90 kN/m² of slope) the lower rafter needs a diameter of 90 mm at 4 m span and 140 mm at 8 m; under tile (1.45 kN/m²) it needs 105 mm at 4 m and 165 mm at 8 m. The tie is never the problem: it requires only 60 to 90 mm across the whole range, and the king post passes at the 60 mm minimum diameter everywhere. Lashed joints, credited with a stated slip-limited capacity of 9.0 kN, suffice at every joint only for the 4 m thatch truss; everywhere else the primary joints need hardwood pegs, from 2 pegs at small spans to 4 pegs at the support of the 8 m tile truss. Extending the same method beyond the design range, the form stops working under tile between 9.0 m, which just passes with a 180 mm rafter, and 9.5 m, which no diameter up to the stated 180 mm maximum pole can carry; under thatch it stops between 11.5 and 12.0 m. In every failing case the lower rafter segment, in combined axial compression and bending, is the member that gives out — not the tie, not the king post, and not the joints. This study is simulated, not measured, and no truss described here has been load-tested.

Zenodo (CERN European Organization for Nuclear Research)
Structural Engineering and Materials Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon