Dynamic Range Modulation via Integrated Universal Range Shifter and Ridge Filter: Enabling Simplified Delivery for FLASH-Enabled IMPT

Abstract Objective: In proton FLASH therapy, using a transmission beam with hypofractionated doses can minimize energy layer switching interruptions to preserve FLASH effect. However, intensity-modulated proton therapy (IMPT) struggles to achieve high FLASH dose rates. This study proposes a novel system that combines universal range shifters (URS) and universal ridge filters (URF) to enable FLASH effect in IMPT. Approach: Water equivalent thickness (WET) optimization was first performed to determine the URS thickness relative to tumor depth, followed by URF modulation to broaden the monoenergetic Bragg peak for longitudinal target coverage. Plan optimization incorporated a spot sparsification algorithm. The proposed system using 218 MeV beams was evaluated in three anatomical sites (brain, liver, and lung tumors) for 10 cases each. Furthermore, this study evaluated the impact of hardware switching speeds and two delivery strategies: (1) bi-URS, constraining URS transitions to binary states, and (2) bi-URF, restricting URF modulation to binary configurations. Main Results: The bi-URS and TB plans achieved mean D98% of 98.30% ± 0.80% versus 98.60% ± 0.90% in brain cases, and 98.40% ± 0.50% versus 97.20% ± 1.00% in liver cases, respectively. Compared to bi-URF, the bi-URS modality significantly reduced delivery time (e.g., brain: 0.305 ± 0.09 s vs. 1.031 ± 0.096 s, p < 0.001). And it demonstrated superior target conformity index (CI) (brain: 0.660 ± 0.020 and liver: 0.653 ± 0.022) compared to TB plans (brain: 0.357 ± 0.082, p < 0.001 and liver: 0.479 ± 0.100, p = 0.012) while maintaining high FLASH average dose rate (ADR) coverage (V40Gy/s of 87.60 ± 15.96% for brain and 91.21 ± 14.42% for liver cases) with URF 20-ms switching speed. Furthermore, it effectively spared the Dmax of hippocampus (bi-URS: 19.00 ± 5.80 Gy, TB: 37.71 ± 17.71 Gy, p=0.041) in brain cases and the residual liver V5 Gy in liver cases (bi-URS: 27.79 ± 10.9%, TB: 68.64 ± 18.72% , p=0.002). However, in lung cases, the CI of the bi-URS modality, while superior to that of the TB modality, remained below the clinical expectation of 0.6. Significance: The combined URS and URF delivery strategy (bi-URS) improved dose conformity of the target, and maintained high FLASH effect coverage in brain and liver cases, demonstrating its potential as a Bragg-peak PBS approach for FLASH radiotherapy.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2026-11-10
DOI
https://doi.org/10.1088/1361-6560/aec05f
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Dynamic Range Modulation via Integrated Universal Range Shifter and Ridge Filter: Enabling Simplified Delivery for FLASH-Enabled IMPT

Zhiyong Yang, H. Cai, Qianqian Lin, Ziyu Wang et al.
Physics in Medicine and Biology
Radiation Therapy and Dosimetry
article

Dynamic Range Modulation via Integrated Universal Range Shifter and Ridge Filter: Enabling Simplified Delivery for FLASH-Enabled IMPT

Zhiyong Yang, H. Cai, Qianqian Lin, Ziyu Wang, Xu Liu, Qingguo Xie, Ping Tan, Kunyu Yang, Bo Pang, Hexiao Wang, Chang Yu, Hong Quan, Qi Zhang, Sheng Zhang
article en

Abstract

Abstract Objective: In proton FLASH therapy, using a transmission beam with hypofractionated doses can minimize energy layer switching interruptions to preserve FLASH effect. However, intensity-modulated proton therapy (IMPT) struggles to achieve high FLASH dose rates. This study proposes a novel system that combines universal range shifters (URS) and universal ridge filters (URF) to enable FLASH effect in IMPT. Approach: Water equivalent thickness (WET) optimization was first performed to determine the URS thickness relative to tumor depth, followed by URF modulation to broaden the monoenergetic Bragg peak for longitudinal target coverage. Plan optimization incorporated a spot sparsification algorithm. The proposed system using 218 MeV beams was evaluated in three anatomical sites (brain, liver, and lung tumors) for 10 cases each. Furthermore, this study evaluated the impact of hardware switching speeds and two delivery strategies: (1) bi-URS, constraining URS transitions to binary states, and (2) bi-URF, restricting URF modulation to binary configurations. Main Results: The bi-URS and TB plans achieved mean D98% of 98.30% ± 0.80% versus 98.60% ± 0.90% in brain cases, and 98.40% ± 0.50% versus 97.20% ± 1.00% in liver cases, respectively. Compared to bi-URF, the bi-URS modality significantly reduced delivery time (e.g., brain: 0.305 ± 0.09 s vs. 1.031 ± 0.096 s, p < 0.001). And it demonstrated superior target conformity index (CI) (brain: 0.660 ± 0.020 and liver: 0.653 ± 0.022) compared to TB plans (brain: 0.357 ± 0.082, p < 0.001 and liver: 0.479 ± 0.100, p = 0.012) while maintaining high FLASH average dose rate (ADR) coverage (V40Gy/s of 87.60 ± 15.96% for brain and 91.21 ± 14.42% for liver cases) with URF 20-ms switching speed. Furthermore, it effectively spared the Dmax of hippocampus (bi-URS: 19.00 ± 5.80 Gy, TB: 37.71 ± 17.71 Gy, p=0.041) in brain cases and the residual liver V5 Gy in liver cases (bi-URS: 27.79 ± 10.9%, TB: 68.64 ± 18.72% , p=0.002). However, in lung cases, the CI of the bi-URS modality, while superior to that of the TB modality, remained below the clinical expectation of 0.6. Significance: The combined URS and URF delivery strategy (bi-URS) improved dose conformity of the target, and maintained high FLASH effect coverage in brain and liver cases, demonstrating its potential as a Bragg-peak PBS approach for FLASH radiotherapy.

Physics in Medicine and Biology
Wuhan University (CN), Wuhan Union Hospital (CN), Huazhong University of Science and Technology (CN)
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon