Approaching the ideal cooling depolarization benchmark in a side-pumped Nd:YAG amplifier by controlling flow distribution and reorganization

In high-power solid-state lasers, thermally induced birefringence and the resulting depolarization are major factors limiting amplifier performance. To establish a rational evaluation benchmark and investigate depolarization behavior, a side-pumped Nd:YAG amplifier module is studied using a coupled fluid–thermal–stress–optical model incorporating temperature-dependent thermal conductivity. An ideal cooling depolarization benchmark is established under the same thermal load and average cooling level, assuming spatially uniform heat dissipation at the crystal surface. The results show that actual depolarization deviates from this benchmark and exhibits a pronounced non-monotonic dependence on the cooling flow rate, indicating that depolarization is not governed solely by the overall cooling capacity. Further analysis attributes this deviation primarily to flow reorganization and redistribution induced by momentum variations at the branch inlet. A performance deviation parameter, U g, and a flow penetration parameter, η m, are introduced to quantify depolarization non-uniformity and flow characteristics. Based on these parameters, the inlet structure is optimized to stabilize the flow distribution. Following optimization, the flow becomes more uniform, and depolarization decreases monotonically with increasing flow rate. Numerical results show that the maximum depolarization intensity is reduced by 3%–7%, averaging approximately 5%. The deviation from the ideal cooling benchmark decreases from 3.77%–5.78% to 0.27%–1.76%, with the average deviation decreasing from 5.10% to 0.65%. Meanwhile, the depolarization non-uniformity parameter U g is reduced by at least a factor of five. These findings demonstrate that regulating flow distribution and suppressing flow reorganization can effectively improve depolarization uniformity and bring practical performance closer to the ideal cooling benchmark.

Authors

Publication Details

Journal
Applied Optics
Published
2026-11-25
DOI
https://doi.org/10.1364/ao.613851
Primary Topic
Solid State Laser Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Approaching the ideal cooling depolarization benchmark in a side-pumped Nd:YAG amplifier by controlling flow distribution and reorganization

Zhenxu Bai, Yulei Wang, Yifu Chen, Zhiwei Lu et al.
Applied Optics
Solid State Laser Technologies
article

Approaching the ideal cooling depolarization benchmark in a side-pumped Nd:YAG amplifier by controlling flow distribution and reorganization

Zhenxu Bai, Yulei Wang, Yifu Chen, Zhiwei Lu, Bowen Tan, Kun Wang
article en

Abstract

In high-power solid-state lasers, thermally induced birefringence and the resulting depolarization are major factors limiting amplifier performance. To establish a rational evaluation benchmark and investigate depolarization behavior, a side-pumped Nd:YAG amplifier module is studied using a coupled fluid–thermal–stress–optical model incorporating temperature-dependent thermal conductivity. An ideal cooling depolarization benchmark is established under the same thermal load and average cooling level, assuming spatially uniform heat dissipation at the crystal surface. The results show that actual depolarization deviates from this benchmark and exhibits a pronounced non-monotonic dependence on the cooling flow rate, indicating that depolarization is not governed solely by the overall cooling capacity. Further analysis attributes this deviation primarily to flow reorganization and redistribution induced by momentum variations at the branch inlet. A performance deviation parameter, U g, and a flow penetration parameter, η m, are introduced to quantify depolarization non-uniformity and flow characteristics. Based on these parameters, the inlet structure is optimized to stabilize the flow distribution. Following optimization, the flow becomes more uniform, and depolarization decreases monotonically with increasing flow rate. Numerical results show that the maximum depolarization intensity is reduced by 3%–7%, averaging approximately 5%. The deviation from the ideal cooling benchmark decreases from 3.77%–5.78% to 0.27%–1.76%, with the average deviation decreasing from 5.10% to 0.65%. Meanwhile, the depolarization non-uniformity parameter U g is reduced by at least a factor of five. These findings demonstrate that regulating flow distribution and suppressing flow reorganization can effectively improve depolarization uniformity and bring practical performance closer to the ideal cooling benchmark.

Applied OpticsVol. 65(34)
Solid State Laser Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon