Wind-Induced Buckling and Load Capacity of a Large Floating-Roof Tank Under Nonuniform Settlement

Large storage tanks are often constructed in coastal areas with relatively poor geological conditions, where foundation settlement and strong wind loads pose significant challenges to safe operation. This study investigates a 100,000 m3 large external floating-roof storage tank. A three-dimensional shell finite element model is established, and geometrically nonlinear analysis combined with the arc-length method is employed to investigate the effects of liquid level, wind direction, and settlement characteristics on the structural response and wind-resistant stability of the tank. The results show that nonuniform foundation settlement changes the initial geometry of the tank wall and causes pronounced circumferential stress redistribution near the bottom edge. The overall radial deformation of the tank is governed primarily by the settlement-induced initial deformation, whereas the additional displacement caused by wind loading is relatively small but strongly direction-dependent. As the liquid level increases, the critical wind load factor increases, and the governing buckling region shifts toward the middle and upper portions of the tank wall. The maximum critical wind load factor among the investigated wind directions is 32.31% higher than the minimum value. When the settlement amplitude increases to approximately 1.5 times the measured value, the wind load-carrying capacity begins to deteriorate at a markedly accelerated rate. In addition, settlement amplitude, harmonic order, maximum slope, and curvature jointly affect structural stability. Under the same settlement amplitude, higher-order settlement components with shorter circumferential wavelengths are more likely to cause localized bending deformation. Therefore, settlement amplitude, circumferential slope, curvature, harmonic composition, and wind direction should all be considered in the inspection and wind-resistance assessment of large storage tanks.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-11-10
DOI
https://doi.org/10.3390/app162211129
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Wind-Induced Buckling and Load Capacity of a Large Floating-Roof Tank Under Nonuniform Settlement

Yonghao Liu, Tuanhai Chen, Wenhua Wang, Zhipeng Leng et al.
Applied Sciences
Structural Load-Bearing Analysis
article

Wind-Induced Buckling and Load Capacity of a Large Floating-Roof Tank Under Nonuniform Settlement

Yonghao Liu, Tuanhai Chen, Wenhua Wang, Zhipeng Leng, Liang Feng, Hengchen Zhang, Sen Gong
article en

Abstract

Large storage tanks are often constructed in coastal areas with relatively poor geological conditions, where foundation settlement and strong wind loads pose significant challenges to safe operation. This study investigates a 100,000 m3 large external floating-roof storage tank. A three-dimensional shell finite element model is established, and geometrically nonlinear analysis combined with the arc-length method is employed to investigate the effects of liquid level, wind direction, and settlement characteristics on the structural response and wind-resistant stability of the tank. The results show that nonuniform foundation settlement changes the initial geometry of the tank wall and causes pronounced circumferential stress redistribution near the bottom edge. The overall radial deformation of the tank is governed primarily by the settlement-induced initial deformation, whereas the additional displacement caused by wind loading is relatively small but strongly direction-dependent. As the liquid level increases, the critical wind load factor increases, and the governing buckling region shifts toward the middle and upper portions of the tank wall. The maximum critical wind load factor among the investigated wind directions is 32.31% higher than the minimum value. When the settlement amplitude increases to approximately 1.5 times the measured value, the wind load-carrying capacity begins to deteriorate at a markedly accelerated rate. In addition, settlement amplitude, harmonic order, maximum slope, and curvature jointly affect structural stability. Under the same settlement amplitude, higher-order settlement components with shorter circumferential wavelengths are more likely to cause localized bending deformation. Therefore, settlement amplitude, circumferential slope, curvature, harmonic composition, and wind direction should all be considered in the inspection and wind-resistance assessment of large storage tanks.

Applied SciencesVol. 16(22)
China National Offshore Oil Corporation (China) (CN), Dalian University of Technology (CN), State Key Laboratory of Coastal and Offshore Engineering (CN)
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon