A Vented Low-Water Causeway: Vent Sizing, Depth Over the Slab, a Closure Rule and What It Gives Up Against a Bridge
Four 900 mm vents carry 5.43 m3/s after inlet limitation; depth over an 18 m slab reaches 0.30 m at 10.46 m3/s, the closure rule, exceeded an expected 6.3 days per year (98.3 percent passable). Cost 36,060 dollars versus a stated 285,000 dollar bridge, with the losses against a bridge stated in numbers. SIMULATED, NOT MEASURED.
Authors
- William Alexander Aldred
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-10
- DOI
- https://doi.org/10.5281/zenodo.24113708
- Primary Topic
- Hydraulic flow and structures
- Type
- preprint