A Batch Solar Water Pasteurizer with Counterflow Heat Recovery: Lethality Priced from Thermal Death Kinetics and Daily Output Sized from Insolation

SIMULATED, NOT MEASURED. A batch solar water pasteurizer is specified in which each treated charge is discharged through a counterflow heat exchanger against the next raw charge, so the treated water's heat is recovered into the incoming batch. Lethality is priced from published-class thermal death kinetics (D and z values) for Escherichia coli, Salmonella spp. and an enteric-virus class represented by hepatitis A virus: the virus class sets the treatment, requiring a hold of 9.0 min at 65 C for a 6-log reduction, while a 1 min hold at 65 C gives it only 0.67 log. With heat-recovery effectiveness 0.70 at 65 C the net energy is 50.23 kJ per litre, 0.160 of the sensible heat of boiling from 25 C. At 5.0 kWh per square metre per day insolation and a collector efficiency of 0.50, one square metre treats 179.2 litres per day; a family unit of 20 litres per day needs 0.11 m2 of collector and a 10.0 litre batch tank in 2 cycles per day, and a school unit of 200 litres per day needs 1.12 m2 and a 50.0 litre batch tank in 4 cycles per day. All results are reproducible calculations from the deposited compute.py; nothing was built or tested.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-10
DOI
https://doi.org/10.5281/zenodo.24108833
Primary Topic
Solar Thermal and Photovoltaic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Batch Solar Water Pasteurizer with Counterflow Heat Recovery: Lethality Priced from Thermal Death Kinetics and Daily Output Sized from Insolation

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Solar Thermal and Photovoltaic Systems
article

A Batch Solar Water Pasteurizer with Counterflow Heat Recovery: Lethality Priced from Thermal Death Kinetics and Daily Output Sized from Insolation

William Alexander Aldred
article en

Abstract

SIMULATED, NOT MEASURED. A batch solar water pasteurizer is specified in which each treated charge is discharged through a counterflow heat exchanger against the next raw charge, so the treated water's heat is recovered into the incoming batch. Lethality is priced from published-class thermal death kinetics (D and z values) for Escherichia coli, Salmonella spp. and an enteric-virus class represented by hepatitis A virus: the virus class sets the treatment, requiring a hold of 9.0 min at 65 C for a 6-log reduction, while a 1 min hold at 65 C gives it only 0.67 log. With heat-recovery effectiveness 0.70 at 65 C the net energy is 50.23 kJ per litre, 0.160 of the sensible heat of boiling from 25 C. At 5.0 kWh per square metre per day insolation and a collector efficiency of 0.50, one square metre treats 179.2 litres per day; a family unit of 20 litres per day needs 0.11 m2 of collector and a 10.0 litre batch tank in 2 cycles per day, and a school unit of 200 litres per day needs 1.12 m2 and a 50.0 litre batch tank in 4 cycles per day. All results are reproducible calculations from the deposited compute.py; nothing was built or tested.

Zenodo (CERN European Organization for Nuclear Research)
Solar Thermal and Photovoltaic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon