Thermal ageing assessment of synthetic ester and mineral oil for transformer applications

Synthetic ester (SE) insulating oil provides better fire safety features compared with conventional mineral oil (MO). However, the long‑term performance of SE under thermal stress is not yet fully understood, and therefore, in this study, the performance of SE and MO subjected to accelerated thermal ageing was compared. Accelerated thermal ageing tests were conducted using samples consisting of the insulating oil (MO or SE), cellulose-based materials (kraft paper and pressboard), and metal catalysts enclosed in sealed glass bottles. The samples were thermally aged at 130 °C for 250, 500, and 750 h. The physicochemical properties (moisture content, interfacial tension, and acidity) were evaluated for both SE and MO. The results showed that SE exhibited higher moisture content than MO throughout the ageing duration, indicating that SE more effectively extracted moisture from the kraft paper. Interfacial tension measurements revealed that SE maintained better stability compared with MO. In addition, SE demonstrated higher acidity that was consistent with ester hydrolysis, whereas MO maintained a relatively stable acidity profile.

Authors

Institutions

Publication Details

Journal
PaperAsia
Published
2026-11-10
DOI
https://doi.org/10.59953/paperasia.v42i5b.1810
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Thermal ageing assessment of synthetic ester and mineral oil for transformer applications

Mohd Shahril Ahmad Khiar, Sharin Ab Ghani, Imran Sutan Chairul, Nur Syahida Akryl Azam et al.
PaperAsia
Power Transformer Diagnostics and Insulation
article

Thermal ageing assessment of synthetic ester and mineral oil for transformer applications

Mohd Shahril Ahmad Khiar, Sharin Ab Ghani, Imran Sutan Chairul, Nur Syahida Akryl Azam, Shaily Hatun Mohamed Saleh, Farah Izzati Asrin
article en

Abstract

Synthetic ester (SE) insulating oil provides better fire safety features compared with conventional mineral oil (MO). However, the long‑term performance of SE under thermal stress is not yet fully understood, and therefore, in this study, the performance of SE and MO subjected to accelerated thermal ageing was compared. Accelerated thermal ageing tests were conducted using samples consisting of the insulating oil (MO or SE), cellulose-based materials (kraft paper and pressboard), and metal catalysts enclosed in sealed glass bottles. The samples were thermally aged at 130 °C for 250, 500, and 750 h. The physicochemical properties (moisture content, interfacial tension, and acidity) were evaluated for both SE and MO. The results showed that SE exhibited higher moisture content than MO throughout the ageing duration, indicating that SE more effectively extracted moisture from the kraft paper. Interfacial tension measurements revealed that SE maintained better stability compared with MO. In addition, SE demonstrated higher acidity that was consistent with ester hydrolysis, whereas MO maintained a relatively stable acidity profile.

PaperAsiaVol. 42(5b)
Technical University of Malaysia Malacca (MY)
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon