A Passive Radiative-Cooling Roof Assembly for Heat-Wave Housing: Computed Cooling Budget and Price per Degree of Indoor Temperature Reduction

SIMULATED, NOT MEASURED. A passive radiative-cooling roof assembly for heat-wave housing — a high-emissivity sky-window coating (solar reflectance 0.95, long-wave emissivity 0.95) over a low-cost fibre-cement substrate with reflective foil underlay, plus an optional 200 kg water night-storage mass — is specified and its cooling budget computed for a 16 m2 room under dry, midlatitude, and humid clear-sky cases. Net cooling flux at peak sun with the surface at ambient temperature: 103.2 W/m2 (dry), 50.9 W/m2 (midlatitude), 4.8 W/m2 (humid). Daily-mean indoor reduction vs a dark roof: 3.75 K, 3.71 K, 3.61 K; vs an ordinary white roof the assembly adds 0.87 K, 0.83 K, 0.79 K. Assembly cost USD 18.00/m2 (USD 288.00 per room), i.e. USD 76.75-79.80 per degree of daily-mean indoor reduction vs the dark roof. Humidity limit printed in the paper: in the humid case sub-ambient daytime cooling effectively vanishes (equilibrium depression 0.4 K at peak sun). All numbers are outputs of the deposited computation script; no hardware was built or tested.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-10
DOI
https://doi.org/10.5281/zenodo.24108519
Primary Topic
Thermal Radiation and Cooling Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Passive Radiative-Cooling Roof Assembly for Heat-Wave Housing: Computed Cooling Budget and Price per Degree of Indoor Temperature Reduction

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Thermal Radiation and Cooling Technologies
article

A Passive Radiative-Cooling Roof Assembly for Heat-Wave Housing: Computed Cooling Budget and Price per Degree of Indoor Temperature Reduction

William Alexander Aldred
article en

Abstract

SIMULATED, NOT MEASURED. A passive radiative-cooling roof assembly for heat-wave housing — a high-emissivity sky-window coating (solar reflectance 0.95, long-wave emissivity 0.95) over a low-cost fibre-cement substrate with reflective foil underlay, plus an optional 200 kg water night-storage mass — is specified and its cooling budget computed for a 16 m2 room under dry, midlatitude, and humid clear-sky cases. Net cooling flux at peak sun with the surface at ambient temperature: 103.2 W/m2 (dry), 50.9 W/m2 (midlatitude), 4.8 W/m2 (humid). Daily-mean indoor reduction vs a dark roof: 3.75 K, 3.71 K, 3.61 K; vs an ordinary white roof the assembly adds 0.87 K, 0.83 K, 0.79 K. Assembly cost USD 18.00/m2 (USD 288.00 per room), i.e. USD 76.75-79.80 per degree of daily-mean indoor reduction vs the dark roof. Humidity limit printed in the paper: in the humid case sub-ambient daytime cooling effectively vanishes (equilibrium depression 0.4 K at peak sun). All numbers are outputs of the deposited computation script; no hardware was built or tested.

Zenodo (CERN European Organization for Nuclear Research)
Thermal Radiation and Cooling Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon