Incinerator Bottom Ash as Aggregate: Leaching Against Washing Cycles and Carbonation Ageing, the Water and Salt Burden, and the Uses That Never Qualify

Municipal incinerator bottom ash (IBA) is produced in large, steady quantities and resembles a coarse aggregate, which makes its use in construction attractive. The obstacle is not appearance or grading but leaching: water passing through the ash mobilises metals, metalloids, chloride, and sulfate. This paper models leaching as a function of two treatments available at modest cost — repeated washing, and carbonation ageing in stockpile — for nine stated elements and salts, and compares the results with stated regulatory-style limits for three uses. SIMULATED, NOT MEASURED: all values are computed from the stated model, not measured on a specific ash. Two treatments behave very differently by element. Chloride and sulfate respond strongly to washing; lead, zinc, copper, chromium, and cadmium respond to both washing and carbonation; molybdenum and antimony respond weakly to both and retain high residual floors of 0.95 and 0.68 mg/kg respectively. Antimony is the controlling element in every use considered. A practical treatment of 3 washes and 12 weeks of ageing qualifies the ash for bound road base, and 5 washes and 12 weeks qualifies it for bound non-structural use, in each case with antimony as the nearest limit. The washing that achieves this uses 7.5 m³ of water per tonne over 3 washes (4.2 m³ fresh with counter-current reuse), removes about 12.94 kg of salt per tonne into the wash water, and produces a first-wash liquor of about 2,927 mg/L dissolved salt that requires treatment — the contamination is transferred, not destroyed. Unbound use in residential settings never qualifies at any wash count or ageing period in this model, because the residual floors for molybdenum and antimony lie above the residential limits before any treatment is applied. That negative result is a property of the floors, not of insufficient washing, and it is printed at full size.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-10
DOI
https://doi.org/10.5281/zenodo.24113080
Primary Topic
Recycling and utilization of industrial and municipal waste in materials production
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Incinerator Bottom Ash as Aggregate: Leaching Against Washing Cycles and Carbonation Ageing, the Water and Salt Burden, and the Uses That Never Qualify

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Recycling and utilization of industrial and municipal waste in materials production
article

Incinerator Bottom Ash as Aggregate: Leaching Against Washing Cycles and Carbonation Ageing, the Water and Salt Burden, and the Uses That Never Qualify

William Alexander Aldred
article en

Abstract

Municipal incinerator bottom ash (IBA) is produced in large, steady quantities and resembles a coarse aggregate, which makes its use in construction attractive. The obstacle is not appearance or grading but leaching: water passing through the ash mobilises metals, metalloids, chloride, and sulfate. This paper models leaching as a function of two treatments available at modest cost — repeated washing, and carbonation ageing in stockpile — for nine stated elements and salts, and compares the results with stated regulatory-style limits for three uses. SIMULATED, NOT MEASURED: all values are computed from the stated model, not measured on a specific ash. Two treatments behave very differently by element. Chloride and sulfate respond strongly to washing; lead, zinc, copper, chromium, and cadmium respond to both washing and carbonation; molybdenum and antimony respond weakly to both and retain high residual floors of 0.95 and 0.68 mg/kg respectively. Antimony is the controlling element in every use considered. A practical treatment of 3 washes and 12 weeks of ageing qualifies the ash for bound road base, and 5 washes and 12 weeks qualifies it for bound non-structural use, in each case with antimony as the nearest limit. The washing that achieves this uses 7.5 m³ of water per tonne over 3 washes (4.2 m³ fresh with counter-current reuse), removes about 12.94 kg of salt per tonne into the wash water, and produces a first-wash liquor of about 2,927 mg/L dissolved salt that requires treatment — the contamination is transferred, not destroyed. Unbound use in residential settings never qualifies at any wash count or ageing period in this model, because the residual floors for molybdenum and antimony lie above the residential limits before any treatment is applied. That negative result is a property of the floors, not of insufficient washing, and it is printed at full size.

Zenodo (CERN European Organization for Nuclear Research)
Recycling and utilization of industrial and municipal waste in materials production
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon