TensorECG: Adaptive-Rank Temporal–Spatial Tensor Compression of Multi-lead ECG Signals with Wavelet and low bit residual refinement

Abstract The rapid growth of long-duration ECG recordings from wearable and ambulatory monitors has created a compression bottleneck for wireless transmission and storage. Existing block- and transform-based methods largely exploit redundancy along only one or two dimensions, offering limited joint modeling of inter-beat and inter-lead correlations. TensorECG addresses this gap by introducing a three-way tensor representation for multi-lead ECG that extends conventional matrix-based approaches to three physiologically meaningful axes: a temporal axis capturing self-similarity across successive heartbeats, a spatial axis capturing inter-lead correlations arising from different projections of cardiac electrical activity, and a morphological axis representing individual beat waveform shapes. A discrete wavelet transform is applied to each beat prior to tensorization, concentrating signal energy into few significant coefficients and reducing the effective dimensionality of the morphological axis. These three dimensions are jointly represented in a unified tensor rather than modeled separately, and the resulting coefficient tensor is compressed via rank-r Tensor-Train SVD, jointly capturing beat and lead correlations. TT-core coefficients are entropy coded, with an optional low-bit residual-refinement layer entropy-coding reconstruction error for additional rate–fidelity control. TT-rank, the key sensitive hyperparameter, is tuned once on a 35-record MIT-BIH training split and fixed for testing on a held-out split and three PhysioNet databases (2–15 leads, 250–1000 Hz). An adaptive-rank DWT+TT variant achieves compression ratios of 18.9–51.6 across 4–12\% PRD targets and clinical validation showing sub-millivolt amplitude and sub-millisecond interval errors

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-10
DOI
https://doi.org/10.21203/rs.3.rs-11396766/v1
Primary Topic
ECG Monitoring and Analysis
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

TensorECG: Adaptive-Rank Temporal–Spatial Tensor Compression of Multi-lead ECG Signals with Wavelet and low bit residual refinement

Hariharan Muthusamy, Ramesh Naidu Laveti, S D Sudarsan, Ashish Pratap
Research Square
ECG Monitoring and Analysis
preprint

TensorECG: Adaptive-Rank Temporal–Spatial Tensor Compression of Multi-lead ECG Signals with Wavelet and low bit residual refinement

Hariharan Muthusamy, Ramesh Naidu Laveti, S D Sudarsan, Ashish Pratap
preprint en

Abstract

Abstract The rapid growth of long-duration ECG recordings from wearable and ambulatory monitors has created a compression bottleneck for wireless transmission and storage. Existing block- and transform-based methods largely exploit redundancy along only one or two dimensions, offering limited joint modeling of inter-beat and inter-lead correlations. TensorECG addresses this gap by introducing a three-way tensor representation for multi-lead ECG that extends conventional matrix-based approaches to three physiologically meaningful axes: a temporal axis capturing self-similarity across successive heartbeats, a spatial axis capturing inter-lead correlations arising from different projections of cardiac electrical activity, and a morphological axis representing individual beat waveform shapes. A discrete wavelet transform is applied to each beat prior to tensorization, concentrating signal energy into few significant coefficients and reducing the effective dimensionality of the morphological axis. These three dimensions are jointly represented in a unified tensor rather than modeled separately, and the resulting coefficient tensor is compressed via rank-r Tensor-Train SVD, jointly capturing beat and lead correlations. TT-core coefficients are entropy coded, with an optional low-bit residual-refinement layer entropy-coding reconstruction error for additional rate–fidelity control. TT-rank, the key sensitive hyperparameter, is tuned once on a 35-record MIT-BIH training split and fixed for testing on a held-out split and three PhysioNet databases (2–15 leads, 250–1000 Hz). An adaptive-rank DWT+TT variant achieves compression ratios of 18.9–51.6 across 4–12\% PRD targets and clinical validation showing sub-millivolt amplitude and sub-millisecond interval errors

Research Square
Centre for Development of Advanced Computing (IN)
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon