A Rain-Ingress Witness for Hand-Dug Wells and Boreholes: Mixing-Derived Detection Floors, Alarm Behaviour and Lead Time from a Low-Cost Conductivity and Temperature Logger

Design study (simulated, not measured) of a conductivity/temperature logger that witnesses storm-driven surface-water ingress into wells. A well-mixed model of dilute ingress (100 uS/cm, 25 C) into well water (600 uS/cm, 17 C) gives a single-sample EC detection floor of 0.20% of well volume (4.72 L in a 2,356 L hand-dug well; 0.71 L in a 353 L borehole). An alarm rule (EC drop of 4 uS/cm vs a trailing 24 h median, sustained 2 h) fires at 0.81% ingress, with no false alarms in a seeded 89-day scored baseline simulation, and gives 2.61 h of warning before the end of a 5%-in-6-h design storm (0.61 h before the next draw in the stated pattern). Drift-limited saline-trend detection is 0.48 uS/cm per week over 90 days. The device witnesses ingress; it does not detect pathogens.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-10
DOI
https://doi.org/10.5281/zenodo.24108769
Primary Topic
Water Quality and Resources Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Rain-Ingress Witness for Hand-Dug Wells and Boreholes: Mixing-Derived Detection Floors, Alarm Behaviour and Lead Time from a Low-Cost Conductivity and Temperature Logger

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Water Quality and Resources Studies
article

A Rain-Ingress Witness for Hand-Dug Wells and Boreholes: Mixing-Derived Detection Floors, Alarm Behaviour and Lead Time from a Low-Cost Conductivity and Temperature Logger

William Alexander Aldred
article en

Abstract

Design study (simulated, not measured) of a conductivity/temperature logger that witnesses storm-driven surface-water ingress into wells. A well-mixed model of dilute ingress (100 uS/cm, 25 C) into well water (600 uS/cm, 17 C) gives a single-sample EC detection floor of 0.20% of well volume (4.72 L in a 2,356 L hand-dug well; 0.71 L in a 353 L borehole). An alarm rule (EC drop of 4 uS/cm vs a trailing 24 h median, sustained 2 h) fires at 0.81% ingress, with no false alarms in a seeded 89-day scored baseline simulation, and gives 2.61 h of warning before the end of a 5%-in-6-h design storm (0.61 h before the next draw in the stated pattern). Drift-limited saline-trend detection is 0.48 uS/cm per week over 90 days. The device witnesses ingress; it does not detect pathogens.

Zenodo (CERN European Organization for Nuclear Research)
Water Quality and Resources Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon