Hours to Danger: A Lumped Thermal Model of Passive Survivability in a Mid-Rise Apartment Block During a Blackout Heatwave, and a Priced Retrofit Bound

SIMULATED, NOT MEASURED. When a blackout coincides with a heatwave, how long does each flat in a mid-rise apartment block stay below a danger threshold, and what does more safe time cost? A lumped single-node thermal model of a 60 m2 flat, resolved by floor (ground, middle, top) and orientation (north, east, south, west), includes fabric conduction, solar gain through glazing, roof solar load, internal gains, thermal mass, and night ventilation. Under a repeating heatwave day of 38 C maximum and 26 C minimum, initial indoor temperature 26 C, and a danger threshold of 32 C indoor air temperature, every unretrofitted flat crosses the threshold: fastest is the top-floor east-facing flat at 32.9 hours, the top-floor west-facing flat crosses at 36.3 hours, and the slowest (ground floor, north-facing) lasts 62.25 hours. The top floor fails first as a class, and flats without night cooling accumulate heat day on day. A retrofit package of external shading, cool-roof and roof-insulation treatment, added thermal mass, and secure night ventilation, priced at $1540 per flat, prevents any modelled flat from crossing within the 120-hour simulation window: at least 87.1 additional safe hours for the worst flat at no more than $17.68 per additional safe hour per flat. The governing planning bound is the worst flat, not the building average.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-10
DOI
https://doi.org/10.5281/zenodo.24109639
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Hours to Danger: A Lumped Thermal Model of Passive Survivability in a Mid-Rise Apartment Block During a Blackout Heatwave, and a Priced Retrofit Bound

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Building Energy and Comfort Optimization
article

Hours to Danger: A Lumped Thermal Model of Passive Survivability in a Mid-Rise Apartment Block During a Blackout Heatwave, and a Priced Retrofit Bound

William Alexander Aldred
article en

Abstract

SIMULATED, NOT MEASURED. When a blackout coincides with a heatwave, how long does each flat in a mid-rise apartment block stay below a danger threshold, and what does more safe time cost? A lumped single-node thermal model of a 60 m2 flat, resolved by floor (ground, middle, top) and orientation (north, east, south, west), includes fabric conduction, solar gain through glazing, roof solar load, internal gains, thermal mass, and night ventilation. Under a repeating heatwave day of 38 C maximum and 26 C minimum, initial indoor temperature 26 C, and a danger threshold of 32 C indoor air temperature, every unretrofitted flat crosses the threshold: fastest is the top-floor east-facing flat at 32.9 hours, the top-floor west-facing flat crosses at 36.3 hours, and the slowest (ground floor, north-facing) lasts 62.25 hours. The top floor fails first as a class, and flats without night cooling accumulate heat day on day. A retrofit package of external shading, cool-roof and roof-insulation treatment, added thermal mass, and secure night ventilation, priced at $1540 per flat, prevents any modelled flat from crossing within the 120-hour simulation window: at least 87.1 additional safe hours for the worst flat at no more than $17.68 per additional safe hour per flat. The governing planning bound is the worst flat, not the building average.

Zenodo (CERN European Organization for Nuclear Research)
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon