Cooling Grain With Night Air: Why Bin Diameter Drops Out of the Aeration Time and Airflow Rate Does Not

Aeration with cool night air is the standard low-cost defence of stored grain against weevils and other stored-grain insects, which largely stop developing below about 15 C. This study sizes the operation for cylindrical wheat bins 2.4 m deep using a cooling-front energy balance. At an airflow of 5 m3/h per tonne, the cooling front advances at 0.0085 m/h regardless of bin diameter, and the bulk mean reaches 15 C after 230.2 hours of suitable air — 28.8 nights at eight usable hours per night — whether the bin holds 5.8 tonnes (2 m diameter) or 52.3 tonnes (6 m). Total fan energy is 10.13 kWh for the 23.2-tonne, 4 m bin at every airflow rate examined, because a faster fan simply finishes proportionally sooner; what the rate buys is calendar time, falling from 460.4 hours at 2.5 m3/h/t to 115.1 hours at 10 m3/h/t. The originated sizing rule is to choose the airflow rate from the nights available before warm weather, not from the bin size, and to budget roughly 29 nights of cool air at the common 5 m3/h/t rate. This study is simulated, not measured. SIMULATED, NOT MEASURED.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-11
DOI
https://doi.org/10.5281/zenodo.24121600
Primary Topic
Agricultural Engineering and Mechanization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Cooling Grain With Night Air: Why Bin Diameter Drops Out of the Aeration Time and Airflow Rate Does Not

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Agricultural Engineering and Mechanization
article

Cooling Grain With Night Air: Why Bin Diameter Drops Out of the Aeration Time and Airflow Rate Does Not

William Alexander Aldred
article en

Abstract

Aeration with cool night air is the standard low-cost defence of stored grain against weevils and other stored-grain insects, which largely stop developing below about 15 C. This study sizes the operation for cylindrical wheat bins 2.4 m deep using a cooling-front energy balance. At an airflow of 5 m3/h per tonne, the cooling front advances at 0.0085 m/h regardless of bin diameter, and the bulk mean reaches 15 C after 230.2 hours of suitable air — 28.8 nights at eight usable hours per night — whether the bin holds 5.8 tonnes (2 m diameter) or 52.3 tonnes (6 m). Total fan energy is 10.13 kWh for the 23.2-tonne, 4 m bin at every airflow rate examined, because a faster fan simply finishes proportionally sooner; what the rate buys is calendar time, falling from 460.4 hours at 2.5 m3/h/t to 115.1 hours at 10 m3/h/t. The originated sizing rule is to choose the airflow rate from the nights available before warm weather, not from the bin size, and to budget roughly 29 nights of cool air at the common 5 m3/h/t rate. This study is simulated, not measured. SIMULATED, NOT MEASURED.

Zenodo (CERN European Organization for Nuclear Research)
Agricultural Engineering and Mechanization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon