The smart mattress cover system for unobtrusive home sleep monitoring and automated sleep quality assessment

Introduction Long-term, non-invasive sleep monitoring is increasingly relevant for the management of chronic conditions; still, existing solutions face a trade-off between clinical accuracy and real-world usability. Most unobtrusive in-bed systems rely on proprietary algorithms, limiting transparency and reproducibility. This study introduces and validates a complete framework for unobtrusive home-based sleep monitoring based on the Smart Mattress Cover System (SMCS), integrating a textile-based pressure matrix and two triaxial accelerometers. Methods Sensors' informations are combined in a reproducible signal-processing pipeline extending the Cole-Kripke algorithm with adaptive thresholding for automated estimation of Total Sleep Time (TST), Wake After Sleep Onset (WASO), number of nocturnal awakenings (nWASO), and Sleep Efficiency (SE). An ablation analysis investigated the individual and combined contributions of accelerometric and pressure-derived signals and adaptive vs. fixed thresholding. The algorithm was developed using data from 13 healthy subjects monitored for 3-13 consecutive nights at home and evaluated against actigraphy. Results The pipeline achieved strong performance for TST ( r = 0.71, ICC = 0.74), moderate performance for nWASO ( r = 0.47, ICC = 0.55), and lower agreement for WASO ( r = 0.37, ICC = 0.22) and SE ( r = 0.29, ICC = 0.29). The ablation analysis showed complementary contributions of accelerometric and pressure-derived signals, with the clearest benefit of their combination for nWASO, while adaptive thresholding effectively accounted for inter-subject and inter-night variability compared to fixed configurations. Discussion These findings provide a promising initial assessment of SMCS feasibility in sleep parameters estimation, highlighting complementary information from the two modalities, particularly for sleep fragmentation. Further development incorporating physiological information and validation against polysomnography in larger, clinically representative cohorts are warranted.

Authors

Institutions

Publication Details

Journal
Frontiers in Digital Health
Published
2026-11-09
DOI
https://doi.org/10.3389/fdgth.2026.1958146
Primary Topic
Sleep and related disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

The smart mattress cover system for unobtrusive home sleep monitoring and automated sleep quality assessment

Nicola Carbonaro, Marco Laurino, Carlotta Marinai, Alessandro Tognetti et al.
Frontiers in Digital Health
Sleep and related disorders
article

The smart mattress cover system for unobtrusive home sleep monitoring and automated sleep quality assessment

Nicola Carbonaro, Marco Laurino, Carlotta Marinai, Alessandro Tognetti, Eleonora Melissa
article en

Abstract

Introduction Long-term, non-invasive sleep monitoring is increasingly relevant for the management of chronic conditions; still, existing solutions face a trade-off between clinical accuracy and real-world usability. Most unobtrusive in-bed systems rely on proprietary algorithms, limiting transparency and reproducibility. This study introduces and validates a complete framework for unobtrusive home-based sleep monitoring based on the Smart Mattress Cover System (SMCS), integrating a textile-based pressure matrix and two triaxial accelerometers. Methods Sensors' informations are combined in a reproducible signal-processing pipeline extending the Cole-Kripke algorithm with adaptive thresholding for automated estimation of Total Sleep Time (TST), Wake After Sleep Onset (WASO), number of nocturnal awakenings (nWASO), and Sleep Efficiency (SE). An ablation analysis investigated the individual and combined contributions of accelerometric and pressure-derived signals and adaptive vs. fixed thresholding. The algorithm was developed using data from 13 healthy subjects monitored for 3-13 consecutive nights at home and evaluated against actigraphy. Results The pipeline achieved strong performance for TST ( r = 0.71, ICC = 0.74), moderate performance for nWASO ( r = 0.47, ICC = 0.55), and lower agreement for WASO ( r = 0.37, ICC = 0.22) and SE ( r = 0.29, ICC = 0.29). The ablation analysis showed complementary contributions of accelerometric and pressure-derived signals, with the clearest benefit of their combination for nWASO, while adaptive thresholding effectively accounted for inter-subject and inter-night variability compared to fixed configurations. Discussion These findings provide a promising initial assessment of SMCS feasibility in sleep parameters estimation, highlighting complementary information from the two modalities, particularly for sleep fragmentation. Further development incorporating physiological information and validation against polysomnography in larger, clinically representative cohorts are warranted.

Frontiers in Digital HealthVol. 8
University of Pisa (IT), Istituto di Fisiologia Clinica (IT), National Research Council (IT)
Sleep and related disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon