Leakage-Controlled Deep Learning for Multi-Analyte Classification and Quantification in Fast-Scan Cyclic Voltammetry

Fast-scan cyclic voltammetry (FSCV) is a widely used electrochemical technique for real-time monitoring of neurotransmitters; however, quantitative interpretation remains dependent on calibration curves generated in simplified in vitro environments that may not accurately reflect the complexity of biological matrices. To address the need for automated FSCV interpretation, we developed a two-stage artificial intelligence (AI) framework integrating analyte classification and concentration prediction. FSCV data were collected for serotonin (5-HT), dopamine (DA), ascorbic acid (AA), and copper (Cu2+) using analyte-specific waveforms, generating a dataset of 30,811 cyclic voltammograms from 192 independent experimental runs. Classification models were evaluated using strict run-level partitioning, while regression performance was additionally assessed using run-level and leave-one-electrode-out (LOEO) validation. Four classification architectures were evaluated: a lightweight image-based convolutional neural network (CNN), a feature-engineered multilayer perceptron (MLP), a transfer-learning ResNet18 model, and a one-dimensional CNN (1D-CNN) trained directly on raw voltammograms. The 1D-CNN achieved the highest classification accuracy (99.8%), outperforming transfer learning (98.68%), the lightweight CNN (97.38%), and the feature-based MLP (76.3 ± 0.6%) while maintaining substantially lower model complexity than ResNet18. Input-channel ablation indicated that waveform-specific acquisition protocols contributed to classification performance. For quantitative analysis, analyte-specific artificial neural networks (ANNs) were trained to predict concentrations from voltammetric morphology, achieving coefficients of determination (R2) of 0.9958, 0.9970, 0.9849, and 0.9561 for 5-HT, DA, Cu2+, and AA, respectively, under the original random sample-level partitioning. However, mean R2 values decreased to 0.74–0.88 under run-level validation and 0.61–0.86 under LOEO validation, with conventional peak-current calibration outperforming the ANNs under LOEO conditions. Integration of classification and regression models into an automated inference pipeline enabled sequential analyte identification and concentration estimation from FSCV data. In an additional end-to-end evaluation using the 1D-CNN classifier and analyte-specific ANN regressors, incorrect analyte routing, although infrequent (approximately 0.8%), produced substantial concentration-prediction errors. These results demonstrate the potential of morphology-aware deep learning for automated FSCV interpretation while highlighting the need for improved quantitative reliability and further validation using independent electrodes, mixed-analyte samples, and complex biological matrices.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-11-08
DOI
https://doi.org/10.3390/s26217059
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Leakage-Controlled Deep Learning for Multi-Analyte Classification and Quantification in Fast-Scan Cyclic Voltammetry

Khan Mohammad Al Farabi, Parth Ganeriwala, Siddhartha Bhattacharyya, Pavithra Pathirathna et al.
Sensors
Electrochemical sensors and biosensors
article

Leakage-Controlled Deep Learning for Multi-Analyte Classification and Quantification in Fast-Scan Cyclic Voltammetry

Khan Mohammad Al Farabi, Parth Ganeriwala, Siddhartha Bhattacharyya, Pavithra Pathirathna, Brianna Isabella Morales Romero, Navoda Udawaththa
article en

Abstract

Fast-scan cyclic voltammetry (FSCV) is a widely used electrochemical technique for real-time monitoring of neurotransmitters; however, quantitative interpretation remains dependent on calibration curves generated in simplified in vitro environments that may not accurately reflect the complexity of biological matrices. To address the need for automated FSCV interpretation, we developed a two-stage artificial intelligence (AI) framework integrating analyte classification and concentration prediction. FSCV data were collected for serotonin (5-HT), dopamine (DA), ascorbic acid (AA), and copper (Cu2+) using analyte-specific waveforms, generating a dataset of 30,811 cyclic voltammograms from 192 independent experimental runs. Classification models were evaluated using strict run-level partitioning, while regression performance was additionally assessed using run-level and leave-one-electrode-out (LOEO) validation. Four classification architectures were evaluated: a lightweight image-based convolutional neural network (CNN), a feature-engineered multilayer perceptron (MLP), a transfer-learning ResNet18 model, and a one-dimensional CNN (1D-CNN) trained directly on raw voltammograms. The 1D-CNN achieved the highest classification accuracy (99.8%), outperforming transfer learning (98.68%), the lightweight CNN (97.38%), and the feature-based MLP (76.3 ± 0.6%) while maintaining substantially lower model complexity than ResNet18. Input-channel ablation indicated that waveform-specific acquisition protocols contributed to classification performance. For quantitative analysis, analyte-specific artificial neural networks (ANNs) were trained to predict concentrations from voltammetric morphology, achieving coefficients of determination (R2) of 0.9958, 0.9970, 0.9849, and 0.9561 for 5-HT, DA, Cu2+, and AA, respectively, under the original random sample-level partitioning. However, mean R2 values decreased to 0.74–0.88 under run-level validation and 0.61–0.86 under LOEO validation, with conventional peak-current calibration outperforming the ANNs under LOEO conditions. Integration of classification and regression models into an automated inference pipeline enabled sequential analyte identification and concentration estimation from FSCV data. In an additional end-to-end evaluation using the 1D-CNN classifier and analyte-specific ANN regressors, incorrect analyte routing, although infrequent (approximately 0.8%), produced substantial concentration-prediction errors. These results demonstrate the potential of morphology-aware deep learning for automated FSCV interpretation while highlighting the need for improved quantitative reliability and further validation using independent electrodes, mixed-analyte samples, and complex biological matrices.

SensorsVol. 26(21)
Florida Institute of Technology (US)
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.