Machine Learning-Based Identification of Patients with Elevated Central Venous Pressure Using Features Extracted from Photoplethysmography and Arterial Blood Pressure Waveforms

Abstract Background Central venous pressure (CVP) is widely used to guide fluid resuscitation and assess right ventricular preload in critically ill and perioperative patients, but requires invasive catheterization associated with procedural risk and resource use. Despite the ubiquity of photoplethysmography (PPG) and arterial blood pressure (ABP) monitoring, their combined use for CVP assessment remains underexplored. Methods We investigated whether machine learning (ML) models using features extracted from PPG and ABP waveforms can discriminate between patients with normal and elevated CVP. Using a large perioperative waveform dataset (MLORD, 17,327 surgical patients), we identified 918 patients with concurrent PPG, ABP, and CVP recordings. For each cardiac cycle, a landmark-based feature extraction tool derived 843 PPG and 846 ABP features, spanning time-, frequency-, and morphology-domain characteristics. Cardiac cycle–level features were summarized at the patient level by computing the mean and standard deviation of each PPG and ABP feature. The maximum CVP in each cardiac cycle was also determined and averaged across all cycles to yield a patient-level mean of cycle-level maximum CVP. Patients were classified as having normal CVP (5–15 mmHg) or elevated CVP (> 15 mmHg) based on this patient-level mean. Model development: We evaluated nine ML classifiers-Light Gradient Boosting Machine (LightGBM), eXtreme Gradient Boosting (XGBoost), Random Forest, histogram-based gradient boosting, multilayer perceptron (MLP), k-nearest neighbors (kNN), Gaussian naive Bayes, support vector classifier (SVC), and logistic regression-for binary classification of normal versus elevated CVP. From 3,378 candidate waveform features per patient (1,686 PPG and 1,692 ABP), we selected 91 features using permutation importance constrained by an events-per-variable rule (maximum number of features set to 10% of the total number of patients). Model hyperparameters were tuned using 3-fold grid search on the training set. The optimal configuration for each classifier was then retrained on the full training set (90% of patients; 413 normal, 413 elevated), and performance was evaluated on a held-out test set (10% of patients; 46 normal, 46 elevated). To obtain robust estimates and confidence intervals, we applied a 100‑iteration bootstrapping procedure to the test set. Results Seven of nine classifiers achieved mean area under the receiver operating characteristic (ROC) curve (AUC) ≥ 0.80 on the test set. Although SVC and XGBoost produced the highest mean AUC and area under the precision–recall curve (AUPRC), LightGBM demonstrated the most balanced overall performance across threshold-dependent metrics at a multi-metric optimized classification threshold. LightGBM achieved a mean AUC of 0.835 (standard deviation 0.042; 95% confidence interval [CI] 0.749–0.916), mean precision 0.827 (0.060; 95% CI 0.727–0.933), mean recall 0.806 (0.054; 95% CI 0.689–0.896), mean F1‑score 0.815 (0.043; 95% CI 0.725–0.893), mean AUPRC 0.841 (0.051; 95% CI 0.739–0.938), mean accuracy 0.817 (0.038; 95% CI 0.739–0.891), and mean specificity 0.830 (0.056; 95% CI 0.722–0.931) which was the best overall performance. Interpretability We applied SHapley Additive exPlanations (SHAP) to the final LightGBM model to quantify the contribution of individual PPG and ABP features to its predictions. Both PPG and ABP features, including both mean and standard deviation measures, had substantial impact on classification, with top features reflecting venous-influenced diastolic PPG morphology and ABP frequency/morphology characteristics consistent with physiologic ventricular interdependence. Conclusions In a large perioperative cohort, combined PPG and ABP waveform features enabled ML-based discrimination between normal and elevated CVP with good performance. These findings suggest that routinely acquired PPG and ABP signals may support minimally invasive screening for elevated CVP and motivate future work on multicenter validation and continuous, noninvasive CVP estimation.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-09
DOI
https://doi.org/10.21203/rs.3.rs-10670041/v1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Machine Learning-Based Identification of Patients with Elevated Central Venous Pressure Using Features Extracted from Photoplethysmography and Arterial Blood Pressure Waveforms

Jeffrey N. Chiang, Ákos Rudas, Walter Rusin, Anna M. Barney et al.
Research Square
Non-Invasive Vital Sign Monitoring
preprint

Machine Learning-Based Identification of Patients with Elevated Central Venous Pressure Using Features Extracted from Photoplethysmography and Arterial Blood Pressure Waveforms

Jeffrey N. Chiang, Ákos Rudas, Walter Rusin, Anna M. Barney, Maxime P. Cannesson, Ravi Pal
preprint en

Abstract

Abstract Background Central venous pressure (CVP) is widely used to guide fluid resuscitation and assess right ventricular preload in critically ill and perioperative patients, but requires invasive catheterization associated with procedural risk and resource use. Despite the ubiquity of photoplethysmography (PPG) and arterial blood pressure (ABP) monitoring, their combined use for CVP assessment remains underexplored. Methods We investigated whether machine learning (ML) models using features extracted from PPG and ABP waveforms can discriminate between patients with normal and elevated CVP. Using a large perioperative waveform dataset (MLORD, 17,327 surgical patients), we identified 918 patients with concurrent PPG, ABP, and CVP recordings. For each cardiac cycle, a landmark-based feature extraction tool derived 843 PPG and 846 ABP features, spanning time-, frequency-, and morphology-domain characteristics. Cardiac cycle–level features were summarized at the patient level by computing the mean and standard deviation of each PPG and ABP feature. The maximum CVP in each cardiac cycle was also determined and averaged across all cycles to yield a patient-level mean of cycle-level maximum CVP. Patients were classified as having normal CVP (5–15 mmHg) or elevated CVP (> 15 mmHg) based on this patient-level mean. Model development: We evaluated nine ML classifiers-Light Gradient Boosting Machine (LightGBM), eXtreme Gradient Boosting (XGBoost), Random Forest, histogram-based gradient boosting, multilayer perceptron (MLP), k-nearest neighbors (kNN), Gaussian naive Bayes, support vector classifier (SVC), and logistic regression-for binary classification of normal versus elevated CVP. From 3,378 candidate waveform features per patient (1,686 PPG and 1,692 ABP), we selected 91 features using permutation importance constrained by an events-per-variable rule (maximum number of features set to 10% of the total number of patients). Model hyperparameters were tuned using 3-fold grid search on the training set. The optimal configuration for each classifier was then retrained on the full training set (90% of patients; 413 normal, 413 elevated), and performance was evaluated on a held-out test set (10% of patients; 46 normal, 46 elevated). To obtain robust estimates and confidence intervals, we applied a 100‑iteration bootstrapping procedure to the test set. Results Seven of nine classifiers achieved mean area under the receiver operating characteristic (ROC) curve (AUC) ≥ 0.80 on the test set. Although SVC and XGBoost produced the highest mean AUC and area under the precision–recall curve (AUPRC), LightGBM demonstrated the most balanced overall performance across threshold-dependent metrics at a multi-metric optimized classification threshold. LightGBM achieved a mean AUC of 0.835 (standard deviation 0.042; 95% confidence interval [CI] 0.749–0.916), mean precision 0.827 (0.060; 95% CI 0.727–0.933), mean recall 0.806 (0.054; 95% CI 0.689–0.896), mean F1‑score 0.815 (0.043; 95% CI 0.725–0.893), mean AUPRC 0.841 (0.051; 95% CI 0.739–0.938), mean accuracy 0.817 (0.038; 95% CI 0.739–0.891), and mean specificity 0.830 (0.056; 95% CI 0.722–0.931) which was the best overall performance. Interpretability We applied SHapley Additive exPlanations (SHAP) to the final LightGBM model to quantify the contribution of individual PPG and ABP features to its predictions. Both PPG and ABP features, including both mean and standard deviation measures, had substantial impact on classification, with top features reflecting venous-influenced diastolic PPG morphology and ABP frequency/morphology characteristics consistent with physiologic ventricular interdependence. Conclusions In a large perioperative cohort, combined PPG and ABP waveform features enabled ML-based discrimination between normal and elevated CVP with good performance. These findings suggest that routinely acquired PPG and ABP signals may support minimally invasive screening for elevated CVP and motivate future work on multicenter validation and continuous, noninvasive CVP estimation.

Research Square
University of California System (US), University of Southampton (GB)
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon